6.18.2 To change the Maximum Setpoint Limit
(Max Setpoint) for the temperature setpoint
Warning
Setting the water temperature to the maximum set
point can result in scalding hot water delivered to the
taps. It is highly recommended that the maximum
setpoint be adjusted to the lowest temperature possible
for the needs of the installation. See following section
to change the maximum setpoint limit (max setpoint).
Make sure the water heater control display is not in a
public area that can result in the temperature settings
being improperly adjusted.
See previous warning on scalds and an ASSE
approved mixing valve.
1. In service mode press the 'Select' button until 'Max
Setpoint' is displayed (Fig. 51).
2. Press 'Set' button to enter setting mode. 'Max Setpoint'
will flash to indicate setting mode (Fig. 52).
3. Press the 'UP' or 'DOWN' buttons to change the
maximum setpoint value. This will limit the maximum
setpoint the user can select. Note: The maximum
setpoint is approximately 180°F (Fig. 53).
4. Press 'Set' button to confirm new 'Max Setpoint' value and
stop setting mode (Fig. 54).