453564042671 PAGE 1 FT
M O N I T O R / D E F I B R I L L A T O R
C O N T R O L S , C O N N E C T I O N S
A N D I N D I C AT O R S

Advertisement

Table of Contents

   Summary of Contents for Philips HeartStart MRx

  • Page 1 453564042671 PAGE 1 FT M O N I T O R / D E F I B R I L L A T O R C O N T R O L S , C O N N E C T I O N S A N D I N D I C AT O R S...
  • Page 2 453564042671 PAGE 1 BK C O N T R O L S , C O N N E C T I O N S A N D I N D I C AT O R S External Power SYNC Mark Ready For Event Use (RFU)
  • Page 3 453564042671 PAGE 2 FT M O N I T O R / D E F I B R I L L A T O R 1 2 - L E A D E C G...
  • Page 4 453564042671 PAGE 2 BK 1 2 - L E A D E C G Electrode Placement for 12-Lead ECG Acquiring the 12-Lead ECG 1. Turn the Therapy Knob to Monitor. 2. Press the 12-Lead soft key. 3. Check for good signal quality. 4.
  • Page 5 453564042671 PAGE 3 FT M O N I T O R / D E F I B R I L L A T O R A L A R M S...
  • Page 6 453564042671 PAGE 3 BK A L A R M S Responding to Alarms 1. Check the patient. 2. Identify the alarm(s) indicated. 3. Silence the alarm(s) by pressing the Menu Select button or one of the Navigation buttons. 4. Address the alarm condition by selecting one of the following options: Alarms Off - Turn the monitoring parameter's alarms off indefinitely, displaying next to the parameter value.
  • Page 7 453564042671 PAGE 4 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G C A R B O N D I O X I D E...
  • Page 8 453564042671 PAGE 4 BK M O N I T O R I N G C O Using the Nasal FilterLine 1. Attach the FilterLine tubing to the CO Inlet port. 2. Check that both nostrils are clear. 3. Position the nasal FilterLine on the face by inserting the tips into the nostrils. 4.
  • Page 9 453564042671 PAGE 5 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G M O N I T O R I N G E C G...
  • Page 10 453564042671 PAGE 5 M O N I T O R I N G E C G Selecting the Lead for ECG Monitoring It is important to select a suitable lead for monitoring so that a QRS complex can be accurately detected. –...
  • Page 11 453564042671 PAGE 6 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G I N V A S I V E P R E S S U R E S...
  • Page 12 453564042671 PAGE 6 BK M O N I T O R I N G I N V A S I V E P R E S S U R E S Changing a Pressure/IP Label 1. Press the Menu Select button.
  • Page 13 453564042671 PAGE 7 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G N O N I N V A S I V E B L O O D P R E S S U R E...
  • Page 14 453564042671 PAGE 7 BK M O N I T O R I N G N B P Preparing 1. Select the appropriately sized cuff. 2. Attach the cuff to the NBP tubing. 3. Insert the NBP tubing into the NBP port. 4.
  • Page 15 453564042671 PAGE 8 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G S p O 2...
  • Page 16 1. Connect the appropriate sensor cable to the HeartStart MRx. 2. Apply the sensor to the patient. 3. If the HeartStart MRx is not turned on, turn the Therapy Knob to Monitor. The pleth wave appears after a few seconds, followed by the oxygen saturation value.
  • Page 17 453564042671 PAGE 9 FT M O N I T O R / D E F I B R I L L A T O R M O N I T O R I N G T E M P E R AT U R E...
  • Page 18 T E M P E R AT U R E To Monitor a Temperature 1. Connect the temperature cable to the HeartStart MRx. 2. Select the correct temperature label for your measurement. 3. Check that the current device settings (including alarm settings) are appropriate for the patient.
  • Page 19 453564042671 PAGE 10 FT M O N I T O R / D E F I B R I L L A T O R V I TA L S I G N S T R E N D I N G...
  • Page 20 V I TA L S I G N S T R E N D I N G Viewing Trending Data 1. Place the HeartStart MRx into Monitor Mode. 2. Press the Menu Select button. 3. Using the Navigation buttons, select Trends and press the Menu Select button.
  • Page 21 453564042671 PAGE 11 FT M O N I T O R / D E F I B R I L L A T O R O P E R AT I O N A L C H E C K...
  • Page 22 O P E R AT I O N A L C H E C K Running the Operational Check Running the Operational Check 1. Verify a charged battery is inserted into the HeartStart MRx. 1. Verify a charged battery is inserted into the HeartStart MRx. 2. Turn the Therapy Knob to 150J.
  • Page 23 453564042671 PAGE 12 FT M O N I T O R / D E F I B R I L L A T O R N O N I N V A S I V E P A C I N G ( T R A N S C U TA N E O U S P A C I N G )
  • Page 24 453564042671 PAGE 12 BK N O N I N V A S I V E P A C I N G ( T R A N S C U TA N E O U S P A C I N G ) Demand Mode Pacing (Requires ECG leads and pads) 1.
  • Page 25 453564042671 PAGE 13 FT M O N I T O R / D E F I B R I L L A T O R Q - C P R...
  • Page 26 Pause for CPR soft key to activate the Pause period. - AED Mode can be configured to provide either a basic or advanced view of Q-CPR on the HeartStart MRx. Basic View displays the CPR Timer and text/voice feedback. Advanced View displays all measurements and feedback available in Manual Defib Mode.
  • Page 27 453564042671 PAGE 14 FT M O N I T O R / D E F I B R I L L A T O R R E A D Y F O R U S E I N D I C AT O R...
  • Page 28 453564042671 PAGE 14 BK R E A D Y F O R U S E I N D I C AT O R The Ready For Use (RFU) indicator is located on the upper, right corner of the device. It indicates the status of the therapy delivery functions of the monitor/ defibrillator using the following definitions: A blinking black hourglass symbol indicates the shock, pacing, and ECG...
  • Page 29 453564042671 PAGE 15 FT M O N I T O R / D E F I B R I L L A T O R I N T E L L I V U E N E T W O R K I N G C O N N E C T I O N A N D S H A R I N G D ATA...
  • Page 30 453564042671 PAGE 15 BK I N T E L L I V U E N E T W O R K I N G C O N N E C T I O N A N D D ATA S H A R I N G 453564042671 Edition 3 July 2009...
  • Page 31 453564042671 PAGE 16 FT M O N I T O R / D E F I B R I L L A T O R I N T E L L I V U E N E T W O R K I N G A D M I T, D I S C H A R G E , T R A N S F E R...
  • Page 32 453564042671 PAGE 16 BK I N T E L L I V U E N E T W O R K I N G A D M I T, D I S C H A R G E , T R A N S F E R 453564042671 Edition 3 July 2009...
  • Page 33 453564042671 PAGE 17 FT M O N I T O R / D E F I B R I L L A T O R W E E K LY S H O C K T E S T...
  • Page 34 4. Press the Charge Button. NOTE: If it becomes necessary to disarm the defibrillator, press [DISARM] 5. If using: - Pads, press the Shock button on the HeartStart MRx to deliver a shock into the test load. - External paddles, simultaneously press the shock buttons located on the paddles to deliver a shock into the test load.

Comments to this Manuals