6. Profibus-DP Communication
6.5. High-speed Link setting in SoftMaster-NM
6.5
High-speed Link setting in SoftMaster-NM
The following table lists the operation sequence of High-speed Link.
Table 17 – Operation sequence of High-speed Link
Software
No.
1
2
3
4
5
SoftMaster-
NM(Slave)
6
7
8
9
10
SyCon
80
Pnet I/F Module 2MLL-PSRA, 2MLL-PSEA User's Guide
Operation
used
Execute
SoftMaster-NM
Create new file
Set SoftMaster-NM
connection
Connect to
SoftMaster-NM
IO Information
Read
Define High-speed
Link project
High-speed Link
Block Setting
High-speed Link
Parameters Write
High-speed Link
Enable
Execute dedicated
Honeywell
Action
On the SoftMaster window, click
Tools > Network Manager.
On the SoftMaster-NM window,
click File > New File. Type project
name and select the PLC series.
Select applicable connection driver
through SoftMaster-NM using
Online > Connect menu.
On the SoftMaster-NM window,
click Online > Connect.
On the SoftMaster-NM window,
click Online > Read IO
Information.
In SoftMaster-NM window, under
Project window, select High-speed
Link.
Double-click the cell on the High-
speed Link window.
For Send : specify Read area
(CPU area)
For Receive : specify Save area
(CPU area)
Click Online > Write Parameter
and verify the applicable High-
speed Link.
Click Online > Enable Link to
enable the applicable High-speed
Link.
For 2MLL-PMEA, start SyCon.
November 2011
R210