Download  Print this page

Table 5 - Communication Specifications Of Pnet Slave I/f Module - Honeywell 2MLL-PSRA User Manual

Pnet i/f module.
Hide thumbs

Advertisement

2. Product Specifications
2.3. Pnet slave I/F module specification
Items
Maximum digital I/O points
Maximum analog I/O channels
Internal consumption current (mA)
Weight (g)
ATTENTION
For more information on how to write the parameter of special module and
I/O module through expansion adapter, refer to SoftMaster and special
module manual.
2.3
Pnet slave I/F module specification
The following table lists the communication specifications of Pnet slave I/F module.
Table 5 – Communication specifications of Pnet slave I/F module
Items
Standard
Interface
Media access
Topology
Amplitude method
Communication interface
Master/Slave
Maximum station count per network
24
Pnet I/F Module 2MLL-PSRA, 2MLL-PSEA User's Guide
Specifications
768 points
(Input Maximum 768 points/output Maximum
768 points, 64-point module x 12 slots)
Input max 122 channels (Maximum TRX 244
byte/2) Output Maximum 96 channels (8
channels X 12 slots)
- 1 word per channel
600
114
Specifications
EN50170 / DIN 19245
RS-485 (electric)
Polling
Bus method
NRZ
Auto baud rate
Slave
99 stations (including master and repeater)
Honeywell
R210
November 2011