Technical data
Technical specifications - RTU3030C
Analog inputs - 12/24 V control output for sensors (X40, X42)
Power supply at terminal L+
Maximum Power
Power
Maximum power of all outputs
(X10 + X11 + X40 + X42)
Antenna connector / wireless interface (XR1A1)
Frequency bands
Antenna connector
Maximum transmit power
HSPA (UMTS)
EDGE (GSM)
GPRS (GSM)
264
Regulated, short-circuit proof, can be configured alternatively, for all outputs:
12 VDC
24 VDC
See below (power)
Alternative:
7.2 W at 24 V
3.6 W at 12 V
With a total of max. 300 mA over all outputs
UMTS
GSM
Quantity
Design
Nominal impedance
WCDMA FDD (B1/2/4/5/6/8/19)
EDGE 1800/1900 MHz
EDGE 850/900 MHz
DCS 1800, PCS 1900
GSM 850/900
Transmission speed (maximum) •
Properties
Transmission speed
Properties
Band 1 (2100 MHz)
Band 2 (1900 MHz)
Band 4 (1900 MHz)
Band 5 (850 MHz)
Band 6 (800 MHz)
Band 8 (900 MHz)
Band 19 (800 MHz)
GSM (850/900 MHz)
DCS (1800 MHz)
PCS (1900 MHz)
1
SMA socket
50 Ω
+24 dBm (Class 3)
+26 dBm (Class E2)
+27 dBm (Class E2)
+30 dBm (Class 1)
+33 dBm (Class 1)
Downlink (HSDPA): 42 Mbps
Uplink (HSUPA): 5.76 Mbps
Multislot class 10
end device class B
coding scheme 1 to 9 (GMSK)
Downlink: 236.8 kbps
Uplink: 236.8 kbps
Multislot class 10
end device class B
coding scheme 1 to 4 (GMSK)