Operating Instructions ACC50
8.
Authorization / disabling of ID-cards
Authorization of ID-cards
Open or close the switch of the timer depending on the required time zone "A" or "B".
Hold the PROGRAMM card in the electromagnetic field..
The yellow LED flashes faster which indicates that the programming mode of the ACC 50 is active
now.
All ID-cards which are held in the electromagnetic field now get access authorization within the
corresponding time zone. The green LED goes on for approx. 1 second after each correct
programming process. The next ID-card can be programmed for access authorization within 8
seconds.
To change to operating mode, hold the PROGRAM card once again in the electromagnetic field. The
ACC 50 changes to operating mode.
The operating mode is indicated by the yelllow LED flashing slowly.
Note: The ACC 50 changes automatically from programming mode to operating mode if no action
takes place within 8 seconds.
Disabling the ID-card
Open or close the switch of the timer depending on the required time zone "A" or "B".
Hold the CLEAR card in the electromagnetic field to activate the disable mode of the ACC 50. The
disable mode is also indicated by the quickly flashing LED.
Hold the card to be disabled in the electromagnetic field. The red LED goes on for approx. 1 second
which indicates that the card was successfully disabled. All authorized ID-cards that you hold in the
field are disabled.
Chang to the operating mode by holding the CLEAR-card once again in the electromagnetic field.
The ACC 50 changes automatically from disable mode to operating mode if no action takes place
within 8 seconds.
Authorization / disabling of ID-cards for both time zones
To authorize or disable an ID-card for time zone "A" and "B", this process must take place once with
open input "timer" and once with closed input "timer".
Disabling ID-cards which are not available
If case of lost of an authorized card the complete memory has to be cleared with the RESET card to
avoid an unauthorized access.