8.1.5.
Adjustment Mode for Base Unit
Set up Base unit in Test mode through USB. (Refer to USB Test Mode (P.43).)
Step
Test Command
1
ts
2
nc
XX
3
nc
4
z
Note:
: Enter key.
: Space key.
Cross Reference
Check and Adjust X501 (Base Unit) Frequency (P.90)
Content
Enter test mode
Adjust the BMC_CLK frequency
Store the adjust value
Exit Test Mode
Description
Make sure the Echo back "TEST" after this command.
XX: 00 - 3F (HEX)
Write the adjust value in XCR register.
Repeat this command until BMC_CLK = 13.824MHz.
If BMC_CLK = 13.824MHz, execute this command to store the adjust
value.
Write the adjust value in FLASH memory.
27
KX-TGP500B04/KX-TPA50B04