2 Machine information
2.3 Test series on the machine
The following prompt is displayed if a manual axis test is not performed after
changes in the prolog and epilog as well as of axis test-specific parameters:
Fig. 2-40: Permanently saving the prolog/epilog program
Message
"Do you want to accept the
changes and check with an axis
test?"
"Do you want to accept the
changes, but not check with an
axis test?"
"Do you want to reject the
changes?"
Note
The option not to perform a manual axis test again in order to retain the 'Tested'
marking despite changes to data relevant for the axis test, must be enabled in the
organizational data.
2-62
Meaning
If the axis test has already been performed
successfully, it is marked as "Tested".
If you press the "Select" softkey, "Tested" is
reset and a one-time successful execution of
the axis test is required in order to be able to
also execute this automatically (e.g. via
maintenance schedules).
If the axis test has already been performed
successfully, it is marked as 'Tested'.
If you press the "Select" softkey, "Tested" is
not reset and a new axis test is not required.
Currently executed changes are rejected. If the
axis test has already been performed
successfully, it is marked as "Tested". If you
press the "Select" softkey, "Tested" is not reset
and a new axis test is not required.
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013