03/2013
3.7 Client-server communication
3.7.1 Synchronization times
Function description
During synchronization, the specified configurations (e.g. for control monitors) are
transferred from the server to the control, and become effective. You can configure
an instant or interval when the machine will perform synchronization. You can also
define the synchronization mode and time zone, in which the machine is located.
Fig. 3-81: Synchronization times - List view
Fig. 3-82: Add synchronization (detail)
Function
Next
synchronization
Mode
Synchronization
schedules
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
Description
Date of the next scheduled synchronization
of the machine with the current
configuration on the server.
Online:
All data is updated.
Offline:
The machine is not
automatically synchronized
with the server settings.
standby:
Only the synchronization
data is updated.
Several synchronization times can be
configured at the same time.
Creates a data record with new
synchronization settings.
Edit a previously defined synchronization
data record.
3 Setting up functions
3.7 Client-server communication
Type
DISPLAY
SELECTION
ACTION
ACTION
3-199