Circularity Test - Siemens SINUMERIK 840D sl Function Manual

Sinumerik integrate amb, amc, amm
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03/2013
Configuring the limit values
With the equability test, one movement is carried out each forwards and
backwards. The characteristics are calculated separately for each direction. As
standard limit values are defined for the characteristics and are the same for both
directions of movement.
Optionally limit values can be entered which can have different values for both
directions for each characteristic.
Fig. 3-11: Measurement series of a equability test on the PC

3.2.2 Circularity test

Parameter description
Parameters for conducting a circularity test:
Function
Name
Channel
Axes 1/2
Center point 1
Center point 2
Diameter
Feedrate
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3.2 Configuring measurements and measurement series
Description
Name of the measurement series
(measurements do not have a name).
Selection of the required channel:
The channel defines the possible axis pairs
in the "Axes" selection list.
Selection from the possible pairs of
geometry axes.
Specification of the center coordinates of
the circle for the first axis.
Specification of the center coordinates of
the circle for the second axis.
Diameter of the circle.
Path velocity of the circular movement.
3 Setting up functions
Type
INPUT
SELECTION
SELECTION
INPUT
INPUT
INPUT
INPUT
3-105