Service Tasks; Leak Test; Changing The Dryer Filter - Waeco AirConServiceCenter ASC5100G Operating Manual

Air conditioning service unit
Hide thumbs Also See for AirConServiceCenter ASC5100G:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 54
ASC5100G
9

Service tasks

9.1

Leak test

Every six months carry out a leak test with an electronic leak detection
device.
9.2

Changing the dryer filter

1. In the basic menu, use the cursor keys  or  to select
"Free selection":
2. Press ENTER to confirm.
3. Skip the query requesting "CAR DATA".
4. Select "Rec/Recycling phase".
5. Set the "Pressure increase test time" to "1".
Press ENTER to confirm.
6. Deselect "Vacuum phase" using "No".
Press ENTER to confirm.
7. Deselect "Filling phase?" using "No".
Press ENTER to confirm.
8. Select "Process start ?".
Press ENTER to confirm.
The service hoses will now be drained and the AirConServiceCenter
basic menu will be activated. The compressor has produced a slight
internal vacuum so that the filter can be replaced with minimal refrig-
erant loss.
9. Switch off the unit.
!
CAUTION!
The following steps may only be performed by qualified personnel.
Wear protective gloves and goggles.