TABLE OF CONTENTS Safety Starting the external unit ..............................................Power supply ....................................................Heat pump domestic hot water ..........................................Heat pump for central heating ............................................ Disposal ..........................................................Ventilation system .................................................. Heatpump ......................................................General information Introduction ........................................................General information prior to installation ......................................
Page 3
Compact P / Compact P Polar - AIR (English) BY NILAN Electric heating element ..............................................Water heating element ..............................................CO 2 sensor ....................................................Cooker hood and EM box ..............................................SHW hot water tank ................................................Other electrical connections ..............................................User selection 1 ..................................................
Page 4
Troubleshooting Emergency operation ..................................................Emergency operation domestic hot water ....................................Emergency operation central heating ......................................Domestic hot water ..................................................Errors and solutions domestic hot water ....................................Central heating ...................................................... Failures and solutions central heating ......................................
Compact P / Compact P Polar - AIR (English) BY NILAN Safety Starting the external unit The external AIR unit is equipped with a compressor heater, which heats up the compressor prior to starting and in case of low outdoor temperatures. This facilitates start-up and extends the compressor’s service life.
Disposal Ventilation system Nilan units mainly consist of recyclable materials. They should therefore not be disposed of with household refuse. Take them to your local recycling centre. Heatpump Concerning disposal of units with heat pumps, it is important to contact the local authorities for information about correct handling of these.
• Installation instructions/Software instructions • User manual • Wiring diagram The instructions can be downloaded from the Nilan website: http://www.nilan.dk/en-gb/frontpage/ download If you have further questions on unit installation after reading the instructions, contact your nearest Nilan distributor, who can be found on www.nilan.dk/en-gb/frontpage/download/dealers.
Page 8
The energy-efficient and low-noise AIR air/water heat pump heats the home via floor heating or low- temperature radiators. It extracts energy from the outside air and functions at temperatures as low as -22 ºC. The heat pump has an electrical power supply to help it to function during very cold periods. The AIR unit has a reversible cooling circuit, which means that it can also be used to cool the home during the summer, using either the floor heating system or fan coils.
Compact P / Compact P Polar - AIR (English) BY NILAN The installation's internal unit Compact P: AIR: Duct connections 20. 2 x 3 kW additional electrical central heating elements Lid for filter changes 21. 8 l expansion tank for central heating circuit Control panel (touch screen), can be detached 22.
The external unit 1. Evaporator element 2. Ventilator 3. Condensate drain with integrated heating cable 4. Heat pump 5. Connectors to internal unit (liquid) 6. Communication to internal unit and electrical connection...
Compact P / Compact P Polar - AIR (English) BY NILAN Overview of temperature sensors Temperature sensors in the unit Temperature sensors outside Temperature sensors in the hot the unit water tank T1: Outdoor air T7: Supply air after heating...
Dimensional drawing Internal unit: Connections: 1. Outdoor air 2. Supply air (inlet) 3. Extract air (outlet) 4. Discharge air Internal unit weight: 257 kg External unit weight: 125 kg All dimensions in mm External unit:...
Compact P / Compact P Polar - AIR (English) BY NILAN Pipe diagram 3/4" flow Buffer tank 3/4" return 1" flow 1" return External AIR unit Internal AIR unit 18. Connection 1" 28. Manometer 19. Flexible hose 1" 29. Safety valve 2.5 bar 20.
Accessories Electrical preheating element for frost protection In longer periods of sub-zero temperatures, the high-efficiency counterflow heat exchanger will ice up. To avoid icing, it is recommended that an electrical preheating element is mounted. The preheating element uses very little energy, but ensures efficient heat recovery without de-icing, thus achieving an overall saving in energy consumption.
Flexible silencing To facilitate later servicing of the unit, we recommend fitting a flexible connection between the unit and the duct system. Nilan's sound damping flexi-hose gives good sound damping both to the duct system and to roof stacks. Trolley A trolley makes it possible to lift the unit of the pallet without physical strain.
When lifting the units with the supplied straps, these must be at an angle of max. 45° from the vertical. Nilan also offers a lifting trolley, with which the unit can be lifted directly off the pallet and into the building. If the filter box is removed, the unit can be manoeuvred through an ordinary door.
Compact P / Compact P Polar - AIR (English) BY NILAN Installing the external unit Installation transport of external unit The external AIR unit is supplied film-wrapped and fastened with straps to a transport pallet. If ground conditions allow, it is recommended that a lifting truck is used to move it.
Sound data The sound from the AIR unit's external unit can be propagated depending on where it is sited relative to the building and the underlying surface, as well as on other surrounding objects and surfaces. Q = 2 (free-standing) Q = 4 (against a wall) Q = 8 (in a corner) Sound effect L...
Compact P / Compact P Polar - AIR (English) BY NILAN Installing the external unit The external unit must always be installed on a firm, vertical and vibration-free surface and secured to some solid material if possible. Account must also be taken of the prevailing wind direction during the heating season, as the performance of the heat pump will be limited if the external unit is exposed to strong winds.
Fixing of external unit to substrate If the external unit is placed in a windy area, e.g. on a roof, it will be necessary to fix it to the substrate using the 6 pre-drilled holes in the base. Possible mounting holes 629,90 347,45 Compressor unit...
Compact P / Compact P Polar - AIR (English) BY NILAN Condensate drain During operation, condensate will form in the external unit’s evaporator, and which has to be run off to a drain. There is a tube measuring xx m connected to the evaporator’s condensation surface which leads to a drain.
Electrical installation Safety ATTENTION All work must be carried out by qualified personnel and in accordance with applicable legislation and regulations. ATTENTION It is important that power is disconnected when working with the unit's electrical components. It is important to check that cables have not been damaged or pinched during connection and use. Connections overview 1.
Compact P / Compact P Polar - AIR (English) BY NILAN User panel Touch panel At delivery of the unit, the Touch panel is integrated in the front, but can be moved if you want to place it in e.g. the kitchen or living room.
Placement of the Touch panel Below is shown how the touch panel can be moved out of the unit. The following page shows how to mount the wall bracket for the Touch panel. 1. Unscrew the two screws at the top of the lid so it can be 2.
Compact P / Compact P Polar - AIR (English) BY NILAN Mounting the wall bracket The Touch panel can be mounted on the wall using the integral wall-bracket. 1. The wall bracket is fixed to the wall with two screws.
Electrical connections unit Safety ATTENTION All work must be carried out by qualified personnel and in accordance with applicable legislation and regulations. ATTENTION It is important that power is disconnected when working with the unit's electrical components. It is important to check that cables have not been damaged or pinched during connection and use. Compact P AIR Heat pump, internal AIR unit Heat pump, external AIR unit...
Compact P / Compact P Polar - AIR (English) BY NILAN Electrical connections accessories External electrical preheating element If Compact P has not been purchased in the Polar version with integral preheating element, there is an option for purchasing an external electrical preheating element for subsequent installation.
Electric heating element If it is wished to control the supply air temperature, it will be necessary to fit a heating element. The electrical post-heating element can be purchased for installation in the air injection channel. The required sensor and unit connector are included. Trim the black RJ45 connector wire at the shrink-fit sleeve and connect the wire to the circuit board.
Compact P / Compact P Polar - AIR (English) BY NILAN Water heating element If it is wished to control the supply air temperature, it will be necessary to fit a heating element. A water heating element can be purchased for fitting in the supply air duct (inlet air), and comes with the necessary sensor and connection to the unit.
Page 30
Electrical connection for 2-way valve 1 . A 24V autotransformer is supplied and should be installed in a suitable position in the unit. ATTENTION The valve must not be connected to a 230V power supply. The wires are routed alongside the duct and drawn through the bushing on top of the Compact P, routed down to the circuit board and mounted in accordance with the wiring diagram.
Compact P / Compact P Polar - AIR (English) BY NILAN sensor It is possible to purchase a CO sensor as an accessory if it is wished to control the ventilation level via the CO level in the dwelling. CAUTION Always disconnect the power supply to the unit before opening the covers or working with electrical installations.
Page 32
7. Reinstall heat exchanger. Remember to reinstall the T4 sensor. Route the wire from the CO sensor to the circuit board and connect it as shown below: Connect the three wires as follows: GND: Blue Out: Black 24V: Brown...
Compact P / Compact P Polar - AIR (English) BY NILAN Cooker hood and EM box There are several benefits from connecting the cooker hood to the home’s ventilation system. Firstly, there is full heat recovery of heat from cooking.
SHW hot water tank The SHW hot water tank is connected to Compact P AIR connection panel as shown below. The SHW tank has its own power supply via a Schuko plug. 1. RJ45 plug for transmitting top temperature (T21), bottom temperature (T22) and anode monitoring in the SHW tank.
Compact P / Compact P Polar - AIR (English) BY NILAN Other electrical connections User selection 1 It is possible to override the unit's functions via an external signal from a potential free contact The User selection function can be used for many purposes, e.g. in the case of a wood burning stove or open fire.
User selection 2 As with User selection 1, it is also possible with User selection 2 to override the unit's functions via an external signal from a potential free contact. The difference is that by activating User selection 2, the control system also transmits an output signal.
Compact P / Compact P Polar - AIR (English) BY NILAN External room sensor If the unit is not intended to be controlled on the basis of the ambient temperature measured by the exhaust air at T3, an external room sensor can be connected.
Common alarm If the unit is located in a place where access is poor or infrequent, and if the control panel is also located here, it may be hard to observe any alarms. An external alarm in the form of a light or acoustic signal, etc., can be connected to the unit. External heat supply Compact P is able to control an external room heating such as electric radiators or a floor heating system.
Compact P / Compact P Polar - AIR (English) BY NILAN External underfloor heating control To avoid the heat pump producing heat when there is no need for it, it is advisable to connect the underfloor heating control on the telestats to AIR/GEO.
The EHD damper is connected via relay 7 and set on the display menu item: Ventilation / Frost protection or de-icing / Frost protection. ATTENTION Damper, geothermal pipe and roof vent are not supplied by Nilan. ATTENTION When using a geothermal pipe, the "Low ventilation a low outdoor temperature" feature cannot...
Active cooling function The AIR unit has a reversible cold circuit, which means that it can be used to actively cool the home, using either the underfloor heating system or fan coils. Active cooling using the underfloor heating There is an external temperature sensor connected to digital input 10. When the contact is closed, the AIR unit goes into cooling mode and cools the home down to a pre-set value.
Compact P / Compact P Polar - AIR (English) BY NILAN Plumbing installation Condensate drain, internal unit Important information Compact P is supplied with a reinforced 20 mm condensate drain hose with integral water trap. ATTENTION The condensate drain should be installed with an even fall of at least 1 cm per m to the nearest drain.
All work must be performed by qualified personnel and in accordance with relevant legislation and provisions. Nilan's hot water tanks are double-enamelled, ensuring long life. The efficient foam insulation protects against unnecessary heat loss. All connection nozzles for water have 3/4" thread and are located in the tank bottom.
Softened water If it is wished to soften water with salt in a Nilan hot water tank, the following must be observed: • The hardness of the water must be at least -2° dh (proportion of alkaline earths 0,4 mmol/l) •...
Central heating Water connection overview, internal unit Front Front Feed to central heating, 3/4" Return from central heating, 3/4" Feed from external unit (hot), 1" Return to external unit (cold), 1" Circulation pump between external and internal units Buffer tank Filling and drain cock Stop valve with particle filter Safety valve (central heating)
Compact P / Compact P Polar - AIR (English) BY NILAN Connections overview, external unit Condensate drain Hole for connections View from below 1. Feed to internal unit (hot), fitted with 1" flexible hose 2. Return from internal unit (cold), fitted with 1" flexible hose...
Check list for the central heating system prior to start-up The check list is used when starting and delivering the system, and it should always be filled in. See the other sections in the manual for further information. Electrical connection and controls Checked - date Notes The power supply is connected and secured in...
Compact P / Compact P Polar - AIR (English) BY NILAN Plumbing connections for accessories Safety group CAUTION A safety device must be connected to the hot water tank. When water is heated to 60 °C, it expands by 2%. A pressure tank could burst without a safety valve keeping excess water out.
Safety group with anti-scald protection The control system contains as standard a temperature limit for domestic hot water of 65 ºC. This setting prevents users from scalding themselves when the hot tap is turned on. It also means that when Compact P is in cooling mode, cooling will stop when the domestic hot water reaches a temperature of 65 ºC.
1. Water heating element 2. Actuator and regulation valve: Danfoss AME 140/24V 0-10V signal, 2-way valve VZ2 Kv0,4 (supplied by Nilan) Kvs-value MUST be checked compared to the supply. Differential pressure: 0.1-0.6 bar At a supply temperature of 60°C, a cooling effect of 20°C over the heater is calculated at maximum heat output.
IMPORTANT, concerning Danfoss Actuator type AME 140: Mandatory procedure for refitting the actuator: 1. Disconnect from mains electricity. Remove actuator cover. 2. Disengage the gear by holding the button under the housing in while screwing the spindle upwards as far as it will go (counter-clockwise) 3.
Compact P / Compact P Polar - AIR (English) BY NILAN Hot water tank The AIR unit can be connected to an external hot water tank (SHW) and to the hot water tank in the Compact P (DHW). A three-way valve, which can be purchased as an accessory, is required.
Connecting to SHW hot water The cold water from the domestic supply is pre-heated in the AIR heat pump’s SHW tank to 45 °C (factory setting 40 °C), after which it is fed to the DHW tank in the Compact P, where it is heated to the desired feed temperature.
Compact P / Compact P Polar - AIR (English) BY NILAN Connecting to DHW hot water If the demand for domestic hot water is so great that the Compact P unit's heat pump cannot cope, the AIR unit can be connected to the DHW tank’s solar coil to help heat up the domestic hot water.
Nilan offers flexible silicing, which, apart from providing a flexible connection between the unit and the duct system, also dampen the passage of sound from the unit to the duct system.
Compact P / Compact P Polar - AIR (English) BY NILAN Extract air Exhaust valves are mounted in the moisture-generating rooms and strategically placed where they can extract the moisture air most effectively. Moisture-generating rooms: • Bathroom • Toilet • Kitchen •...
Initial regulation Important information ATTENTION For the ventilation system to operate optimally, it is important that initial regulation is carried out correctly. We recommend having this done by experts. It is important to measure the total supply (inlet) air and extract (outlet) air. The system must have a minimum vacuum, i.e.
Compact P / Compact P Polar - AIR (English) BY NILAN Startup Central heating Filling with water ATTENTION Before starting the heat pump and the circulation pumps, the central heating circuit connected to the external unit must first be filled with water Fill the central heating circuit with water via the feed cock until the correct water pressure is obtained.
Troubleshooting Emergency operation Emergency operation domestic hot water If an error occurs in the controller or components in the Compact P, and the unit therefore stops, it will not be able to produce domestic hot water. If the installer is not able to come right away or the error happens outside the opening hours, and you therefore cannot contact the installer, there is a possibility to get hot water by setting the unit into emergency mode.
Compact P / Compact P Polar - AIR (English) BY NILAN Emergency operation central heating If an error occurs in the controller or components in the AIR air/water heat pump, and the heat pump therefore stops, it will not be able to heat up the house by the central heating.
Domestic hot water Errors and solutions domestic hot water Problem Possible cause Solution The unit produces insufficient domestic hot water The filters may be blocked so that insufficient air Change the filters and, if necessary, change the is reaching the unit. filter change period to a shorter Interval.
Page 63
Compact P / Compact P Polar - AIR (English) BY NILAN...