Bosch Rexroth IndraDrive FC Series Operating Instructions Manual page 42

Drive controllers frequency converters
Table of Contents

Advertisement

40/69
Bosch Rexroth AG
Instructions for Use
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Rexroth IndraDrive Fc Drive Controllers Frequency Converters FCS01
At the Bottom of the Device (Motor Output)
Fig.5-8:
Motor Output Jumper in Position "1"
Setting
Position
0
1
2
Fig.5-9:
Jumper Position at the Bottom
Operation
Position of jumper
at top of device
IT mains
0
Residual-current-
0, 1 or 2
operated
circuit-
breaker
Fig.5-10:
Settings
Be aware that the specified degree of radio interference suppres‐
sion may change with the different settings. For details please
see chapter 6 "EMC Measures for Design and Installation".
DOK-INDRV*-FCS01******-IT01-EN-P
Effect
Operation at the IT mains
Standard position (condition as supplied)
Reduced leakage current; operation with
residual-current-operated circuit-breaker
Position of jumper
Explanation
at bottom of device
0
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indradrive fcs01 series

Table of Contents