System appliance electrical connections.
1
2
Control Box
4
3
Brown
7
2
3
Red
16
Fig. 42 System wiring diagram
Key to components:
[1]
Remote junction box (10 way).
[2]
Air pressure switch
[3]
High limit thermostat
[4]
Frost thermostat
[5]
Earth stud
[6]
Terminal connector block
[7]
Control thermostat
[8]
Flue manual reset overheat thermostat
[9]
Boiler manual reset overheat thermostat
[10] Demand neon
[11] Burner socket
[12] Mode switch
[13] Service socket connection
[14] Burner plug
[15] Burner control box
[16] Pump
Greenstar Danesmoor External
ErP+
and External System
Junction Box/Wiring Centre
5
9
8
N
L
ErP+
6720821725 (2018/04)
6
L
N
1
2
3
Green/Yellow
Brown
10
11
14
Green/Yellow
15
Installation
12
Blue
13
L3 N
L2 L1
N
L
L3 N
L2 L1
Riello Burner Control Box
L
N
M
27