Oil Burner And Pump - Bosch Worcester Greenstar Danesmoor External Regular ErP+ 12/18 Installation, Commissioning And Servicing Instruction Manual

Floor standing oil-fired condensing boiler using room sealed flue for fully pumped open vent or sealed central heating systems and domestic hot water cylinders
Hide thumbs Also See for Worcester Greenstar Danesmoor External Regular ErP+ 12/18:
Table of Contents

Advertisement

S
P
R
Fig. 32 Condensate
[P]
Condensate collection sump
[R]
Manifold access cover
[S]
Screws
Fire valve
Where required, check that the oil supply pipe has a fire valve fitted
externally to the building with the fire valve sensor located within the
appliance case.
A fire valve sensor clip [1] is provided for this purpose on the support
bar between the side panels.
2
1
Fig. 33 Fire valve clip
[1]
Fire valve clip
[2]
Fire valve label
The fire valve label [2] states that the fire valve should be rated at 85°C
or above to avoid nuisance cut outs.
Greenstar Danesmoor External
ErP+
and External System
5.7
500ml
Oil burner nozzle
Before removing or fitting a new nozzle refer to figure 34:
6720808218-37.1Wo
▶ Remove the screws [1] from the blast tube [2] and remove the blast
▶ Unplug the HT leads [4]
▶ Loosen the screw [3] securing the break plate[5] and slide the unit
▶ Use a suitable spanner to stop the nozzle body turning
▶ Remove the nozzle [8]and secure the new nozzle, hand tight
▶ Tighten the nozzle utilising the two spanners used during removal, do
▶ Refit the break plate ensuring that the photocell and the break plate
▶ Reconnect the HT leads [4]
▶ Refit the blast tube [2] and secure with the screws [1]
6720820042-35.2Wo
Fig. 34 Nozzle access
ErP+
6720821725 (2018/04)

Oil burner and pump

CAUTION: MAINS SUPPLIES
▶ Isolate the oil & water mains supply before starting
any work and observe all relevant safety precautions.
NOTICE: Nozzle orifice contamination
▶ to avoid contamination do not dismantle, clean or
touch the nozzle tip
tube
There is a recirculation tube fitted to the 12/18 models,
this does not need to be removed from the blast tube
off
not overtighten
hole [5] are aligned and secure with the screw [3] into the seating
provided [7]
2
3
7
4
Installation
1
5
8
6
6720821683-12.1Wo