These manual apply to the CA64T v1.4 module with software version 4.00.
The synoptic board with software version 4.00 can interface with the CA-64 alarm control
panel, the INTEGRA series control panels, or the STAM-1 monitoring station. The module
automatically recognizes the equipment it is connected to.
DIP-switches
RS sockets for
expansion boards
(only STAM-1)
RS 232 to STAM-1
monitoring station
card
®
T 3,15A
ON
1 2 3 4 5 6 7 8
J27
J28
J24
RS 232 to computer
(program GUARD64 or GUARDX)
Figure 1. View of the electronics board.
SYNOPTIC BOARD
CA-64 PTSA
LED
LED 97
LED 65
LED 96
LED 128
ca64ptsa_e 02/05
LED 1
LED 8
LED 16
LED 24
LED 64
LED 32

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA-64 PTSA and is the answer not in the manual?

Questions and answers

Summary of Contents for Satel CA-64 PTSA

  • Page 1 SYNOPTIC BOARD CA-64 PTSA ® These manual apply to the CA64T v1.4 module with software version 4.00. ca64ptsa_e 02/05 The synoptic board with software version 4.00 can interface with the CA-64 alarm control panel, the INTEGRA series control panels, or the STAM-1 monitoring station. The module automatically recognizes the equipment it is connected to.
  • Page 2 SATEL CA-64 PTSA 1. P OWER SUPPLY CONNECTION The board has its own independent power supply with a battery backup. To energize the board, connect the alternating voltage of 17..24 V from a mains transformer rated at least at 30VA to the AC inputs.
  • Page 3 CA-64 PTSA SATEL Zones: Bypass 11110000 Trouble - long violation: 10101000 Trouble – no violation: 10100000 Tamper alarm: 10000000 Alarm: 10101010 Tamper: 11111110 Violation: 11111111 Tamper memory: 10000000 Alarm memory: 10101010 Zone OK: 00000000 Partitions: Entry time delay: 11111110 Exit time delay < 10 s.: 10101010 Exit time delay >...
  • Page 4 SATEL CA-64 PTSA Fig. 2. Mode of time sequence presentation in LCD keypad. Programming of the time sequence in the Dload64 and DloadX programs is effected by means of the mouse: move the cursor to select the time segment and click on it to switch the LED illumination ON or OFF.
  • Page 5 NTERACTION WITH THE MONITORING STATION The board is designed to work in conjunction with the SATEL STAM-1 monitoring station, based on software version 3.17 or later. The purpose of the board is visualization of the state of monitored objects by means of LEDs e.g. on a city map or a site plan. Each subscriber's status can be shown with two LEDs, which permits legible representation of the supervised objects when LEDs of different colors (e.g.
  • Page 6 SATEL CA-64 PTSA synoptic boards can be connected in one system, which makes up 4032 visualized objects. If one board only is used and the number of subscribers in the system exceeds 64, the board will only show the subscribers with numbers from 1 to 64 (subscriber no. 1 on LEDs 1 and 2, subscriber no.
  • Page 7 CA-64 PTSA SATEL LED 1 anode color 1 (e.g. red) subscriber 1 LED 1 anode color 2 (e.g. green) LED 2 anode color 1 (e.g. red) subscriber 2 LED 2 anode color 2 (e.g. green) LED 3 anode color 1 (e.g. red) subscriber 3 LED 3 anode color 2 (e.g.
  • Page 8 The latest EC declaration of conformity and certificates are available for downloading on website www.satel.pl SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl...

Table of Contents