External Control Commands

Overview

The XCI-SX1/V3 can be controlled externally from a
host device via a serial communication and telnet using
such communication softwares as "HyperTerminal" or
"Tera Term."
Serial Communication
Specifications
The serial communication system for the XCI-SX1/V3
is an asynchronous method compliant with RS-232C.
The following table shows the transmission control
specifications.
115200/57600/38400/19200/9600/4800 [bps]
Baud rate
Default setting: 38400 [bps]
Data bits
8
Parity
None
Stop bit
1
Flow control
None
Authentication
None
The external interface for serial communication is RS-
232C DCE (Data Communication Equipment) whose
connector form is D-sub 9pin(male).
When connecting the XCI-SX1/V3 to a PC, use a cross
cable.
External Control Commands
XCI-SX1/V3 RS-232C connection
6PIN
TXD
1
RXD
2
GND
3
NC
4
NC
5
NC
6
Telnet Communication
Specifications
The following table shows the specification for telnet
communication.
Port Number
23
Authentication
login, password authentication
For the login, use the following login account.
user:
admin
password: 1227
Telnet Authentication
Specification
When you access the XCI-SX1/V3 from external
equipment, the following message appears on the
monitor.
SMARTCAM Telnet Server
SMARTCAM login:
Enter the login account and then the password.
SMARTCAM Telnet Server
SMARTCAM login: admin
password:
******
D-SUB 9PIN
1
2
RXD
3
TXD
4
5
GND
6
7
8
9
22