LIGHTS/METERS/SWITCHES
COMBINATION METER
POWER/GROUND LINE INSPECTION
If any indication in the combination meter is abnormal,
check the following item.
Remove the front cowl (page 2-2).
Remove the dust cover.
Disconnect the combination meter 16P (Gray) connector.
Check the following at the wire harness side connector
terminals of the combination meter.
16P CONNECTOR
DUST COVER
Power input line
16P CONNECTOR
Measure the voltage between the Black wire terminal (+)
and body ground (–).
BLACK
There should be battery voltage with the combination
switch ON.
If there is no voltage, check the fuse (15 Amp) and open
circuit in Black wire.
Back-up voltage line
16P CONNECTOR
Measure the voltage between the Red/white wire terminal
(+) and body ground (–).
There should be battery voltage at all times.
RED/ WHITE
If there is no voltage, check the fuse (10 Amp) and open
circuit in Red / White wire.
Ground line
Measure the continuity between the Green wire terminal
and body ground.
GREEN
There should be continuity.
If there is no continuity, check for open circuit in Green wire.
17-5