4-1-2 Recording Time Code and User Bit Values

There are the following four ways of recording time code:
• Internal Preset mode, which records the output of the
internal time code generator, set beforehand to an initial
value. The following run modes can be selected.
- Free Run: Time code advances continually.
- Rec Run: Time code advances only during recording.
• Internal Regen mode, which records the output of the
internal time code generator, initialized to time code
following continuously upon the time code of the last
frame of the last clip on the disc.
• External Regen mode, which records the output of the
internal time code generator, synchronized to an external
time code generator. As the external input, the time code
input to any of the following connectors can be selected.
Time code recording mode
Internal Preset Free Run
Internal Preset Rec Run
Internal Regen
External Regen (TIME CODE IN
connector: LTC)
External Regen (VIDEO IN connector:
VITC)
External Regen (i.LINK connector: TC)
External Regen (i.LINK connector:
VITC)
External Regen (SDI IN connector:
SMPTE RP188 LTC)
External Preset (TIME CODE IN
connector: TC)
External Preset (i.LINK connector: TC)
To record the time code after setting an
initial value
Set the following extended menu items to the specified
values.
• Item 626 "TC MODE": "int preset"
• Item 627 "RUN MODE": "free run" or "rec run"
• Item 628 "DF MODE": "on (df)" or "off (ndf)"
See 8-3-2 "Extended Menu Operations" (page 102) for
more information about how to make extended menu
settings.
Then set an initial value as described below, and carry out
recording (see page 53).
To set an initial value
Do as follows.
50
4-1 Recording
- TIME CODE IN connector: LTC
- VIDEO IN connector: VITC
- SDI IN connector: SMPTE RP188 LTC
-
• External Preset mode, which directly records the input of
an external time code generator. As the external input,
the time code input to any of the following connectors
can be selected.
- TIME CODE IN connector: TC
-
As shown in the following table, you can switch between
different time code recording modes by combining
extended menu items settings with video input signal
selections.
Extended menu item setting or video input signal selection
Item 626
Item 627
int preset
free run
rec run
int regen
ext regen
rp188 regen
ext preset
S400 (i.LINK) connector: TC or VITC
S400 (i.LINK) connector: TC
VIDEO INPUT SEL
button
SDI/CMPST/SG
i.LINK
SDI/CMPST/SG
i.LINK
Item 629
tc
vitc
tc
vitc

Hide quick links: