Technical Data - Siemens Expert Series Operating Note

For tempering units and hot runners
Table of Contents

Advertisement

10

TECHNICAL DATA

INPUTS
SURVEY OF THE INPUTS
Input
Used for:
INP1
x (process value)
INP2
Heating current, ext. set-point
di1
Operation disabled, switch-over to
second setpoint SP.2, external
di2
setpoint SP.E, fixed output value Y2,
di3
manual operation, controller off,
disabling of manual key, reset of
stored alarms, boost, parameters 1/2,
safety temperature limiter, start/stop
with local operation, sensor operating
mode, level alarm, flow alarm
PROCESS VALUE INPUT INP1
Resolution:
Decimal point:
Limiting frequency:
Scanning cycle:
Measured value
correction:
Thermocouples
Input impedance:
Effect of source resistance:
Table 1 Thermocouple ranges
Thermocouple
L
Fe-CuNi (DIN)
J
Fe-CuNi
K
NiCr-Ni
N
Nicrosil/Nisil
S
PtRh-Pt 10%
R
PtRh-Pt 13%
special
Table 2 Resistance transducers
Type
Sensor current Range
Pt100
0,2mA
Pt1000
Resistance
Operating note KS 50-1 TCont
> 14 Bit
0 to 3 decimals
adjustable 0.000...9999 s
100 ms
2-point or offset correction
1 MW
1 mV/W
Range
-100...900°C
-100...1200°C
-100...1350°C
-100...1300°C
0...1760°C
0...1760°C
-25 ... 75 mV
-200...850°C
-200...850°C
4500 W
Cold junction compensation
Max. additional error
Sensor break monitoring
Sensor current:
Operating sense configurable
Resistance thermometer
Connection:
Lead resistance:
Input circuit monitor:
Resistance measuring range
The BlueControl software can be used to
match the input to the sensor KTY 11-6
(characteristic is stored in the controller).
Physical measuring range:
Linearization segments:
Current and voltage signals
r
Table 3 (page 24 )
Span start, end of span: anywhere within measuring
Scaling:
Linearization:
Accuracy
-148...1652°F
ß 2K
-148...2192°F
ß 2K
-148...2462°F
ß 2K
-148...2372°F
ß 2K
32...3200°F
ß 2K
32...3200°F
ß 2K
Accuracy
-328...1562°F
ß 1K
-328...1562°F
ß 2K
ß 0.1%
23
TECHNICAL DATA
0.5 K
1 mA
3-wire
max. 30 Ohm
Break and short circuit
0...4500 Ohm
16
range
selectable -1999...9999
16 segments, adaptable
with BlueControl
Resolution (Ô)
0.1 K
0.1 K
0.2 K
0.2 K
0.2 K
0.2 K
0.1%
0.01%
Resolution (Ô)
0.1K
0.1K
0.051%
Slave telegram

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ks50-1 tcont

Table of Contents