Status Codes - Class 4 - Fronius Primo 3.0-1 Operating Instructions Manual

Hide thumbs Also See for Primo 3.0-1:
Table of Contents

Advertisement

Available languages

Available languages

Code
Description
301
Overcurrent (AC)
302
Overcurrent (DC)
Power stage set overtempera-
303
ture
304
Internal temperature too high
LOW PV OUTPUT
Intermediate circuit voltage too
306
low for feeding energy into the
grid
LOW PV VOLTAGE
307
DC input voltage too low for
feeding energy into the grid
IMPORTANT! Due to the low level of insolation, the status codes 306 (LOW PV OUTPUT) and 307 (LOW PV
VOLTAGE) are displayed routinely every morning and evening. These status codes do not indicate any kind of
fault.
308
Intermediate circuit overvolt-
age
DC input voltage MPPT 1 too
309
high
313
DC input voltage MPPT 2 too
high
Status codes –
Some of the class 4 status codes necessitate intervention by a Fronius-trained service
Class 4
technician.
Code
Description
Unable to communicate with
401
the power stage set
Power stage set temperature
406
sensor faulty
Internal temperature sensor
407
faulty
Direct current feeding in de-
408
tected
Fixed voltage mode has been
selected instead of MPP volt-
412
age mode, and the fixed volt-
age has been set to too low or
too high a value.
Behaviour
Short-term interruption while
feeding energy into the grid
due to overcurrent in the invert-
er.
The inverter resumes with its
start-up routine.
Short-term interruption while
feeding energy into the grid
due to overtemperature
The inverter resumes with its
start-up routine.
Short-term interruption while
feeding energy into the grid
The inverter resumes with its
start-up routine.
Short-term interruption while
feeding energy into the grid
The inverter resumes with its
start-up routine.
Behaviour
The inverter will automatically
attempt to connect again and,
if possible, will resume feeding
energy into the grid.
-
Remedy
Fault is rectified automatically;
if this status code is displayed
all the time: notify a Fronius-
trained service engineer
Purge openings for cooling air
and heat sink if necessary;
fault is rectified automatically;
if this status code keeps recur-
ring, contact your system engi-
neer
Fault is rectified automatically;
if this status code occurs when
there is sufficient insolation,
contact your system engineer
Fault is rectified automatically;
if this status code is displayed
all the time: notify a Fronius-
trained service engineer
Remedy
If the status code is displayed
all the time: Notify a Fronius-
trained service technician.
If this status code keeps recur-
ring, contact your system engi-
neer.