The Setup menu items

Standby

Manual activation / deactivation of Standby mode
-
-
-
-
-
-
-
Switching off Standby mode (manually switching off feeding energy into the grid):
1
2
"STANDBY" and "ENTER" appear alternately on the display.
Standby mode is now active.
The Startup LED shows steady orange.
Resuming feeding energy into the grid:
"STANDBY" and "ENTER" appear alternately on the display when in Standby mode.
1
The "Standby" menu item is displayed.
At the same time, the inverter enters the startup phase.
The operating state LED shows steady green when feeding energy into the grid has been
resumed.
WiFi Access
Activating / deactivating the WiFi Access Point. This is necessary for setting up or adjusting
Point
system monitoring using the Datamanager web interface, for example. If no Datamanager
is detected by the inverter, [not available] is displayed
Setting range
26
No energy is fed into the grid.
The Startup LED will show steady orange.
In the display, STANDBY / ENTER are alternately displayed
In Standby mode, no other menu item at menu level can be accessed or adjusted.
The automatic switchover into the "NOW" display mode after 2 minutes of keyboard
inactivity does not occur.
Standby mode can only be terminated manually by pressing the "Enter" key.
Pressing "Enter" at any time will cause energy to resume feeding into the grid, as long
as there is no error (state code)
Select the "Standby" item
Press "Enter" function key
Press the "Enter" function key to resume feeding energy into the grid

WiFi Access Point

[stopped]
Activate WiFi AP?
WiFi Access Point
[active]
The SS-ID (SS) and password (PW) are displayed.
To activate the WiFi Access Point Press the "Enter" key