LM-K2 series primary side (coil) dimensions

For mounting of the primary side, use the hexagon socket head cap screw (material is SCM435 and the lower yield point is
2
900 N/mm
or more).
The power lead wires, grounding lead wires, and thermistor lead wires are for fixed wiring. Securely fix it to the structure.
Minimum bending radius of the lead wire is recommended to be six times or more (reference value) the standard overall
diameter of the lead wire. Select the cable used for the moving part considering the speed of linear servo motor and the
flexing radius.
LM-K2P1A-01M-2SS1, LM-K2P1C-03M-2SS1
Model
Variable dimensions
L
LM-K2P1A-01M-2SS1
138
LM-K2P1C-03M-2SS1
330
Power lead wire (U, V, W): Black, Grounding lead
wire (E): Green/yellow, Effective length: 300 mm
L
M (cumulative pitch error: ±0.3)
(15.5)
48 ± 0.2
B-M6 screw depth 7
(for primary-side mounting)
(6)
K
Thermistor lead wire (G1, G2): Black, 2
wires - AWG 20 (standard overall diameter:
2.12 mm), Effective length: 300 mm
M
K
B
2 × 48 = 96
115
2 × 3
6 × 48 = 288
307
2 × 7
+30
300
0
(Effective lead wire length)
26.5
50
15
PVC tube
Wire mark
15
40
+30
300
17
0
(Effective lead wire length)
H1
H2
3
3.5 or more
1.5
2.5 or more
Round crimp terminal (1.25-4)
Secondary side
54
X
1
46
55 ± 0.1
Round crimp terminal (1.25-4)
Power/grounding lead
wires
Size
Standard
overall
diameter
AWG 20
2.12
AWG 16
2.7
Mold (omitted)
2-C0.5
Mounting part
H1
H2
Detailed view of section X
[Unit: mm]
5 Linear servo motor
69
5.6 LM-K2 series
5