4.3

Selection example of wires

Selection conditions of wire size are as follows.
• Construction condition: Single wire set in midair
• Wiring length: 30 m or shorter
Refer to the following when using LM-F series linear servo motor.
Wire size selection example 2 (HIV wire)
Wire size selection examples for HIV wires are indicated below.
Example of selecting the wire sizes
■Wire size selection example 1 (HIV wire)
Linear servo motor (primary side)
LM-H3P2A-07P-BSS0
LM-H3P3A-12P-CSS0
LM-H3P3B-24P-CSS0
LM-H3P3C-36P-CSS0
LM-H3P3D-48P-CSS0
LM-H3P7A-24P-ASS0
LM-H3P7B-48P-ASS0
LM-H3P7C-72P-ASS0
LM-H3P7D-96P-ASS0
LM-U2PAB-05M-0SS0
LM-U2PAD-10M-0SS0
LM-U2PAF-15M-0SS0
LM-U2PBB-07M-1SS0
LM-U2PBD-15M-1SS0
LM-U2PBF-22M-1SS0
LM-U2P2B-40M-2SS0
LM-U2P2C-60M-2SS0
LM-K2P1A-01M-2SS1
LM-K2P1C-03M-2SS1
LM-K2P2A-02M-1SS1
LM-K2P2C-07M-1SS1
LM-K2P3C-14M-1SS1
■Wire size selection example 2 (HIV wire)
LM-F series linear servo motor (primary side)
LM-FP2B-06M-1SS0
4 CONNECTION OF SERVO AMPLIFIER AND LINEAR SERVO MOTOR
22
4.3 Selection example of wires
2
Wire [mm
]
For power/grounding (U/V/W/E)
1.25 (AWG 16)
2 (AWG 14)
1.25 (AWG 16)
2 (AWG 14)
2 (AWG 14)
3.5 (AWG 12)
1.25 (AWG 16)
2 (AWG 14)
3.5 (AWG 12)
1.25 (AWG 16)
2 (AWG 14)
1.25 (AWG 16)
3.5 (AWG 12)
3.5 (AWG 12)
Natural cooling
Liquid cooling
For thermistor (G1/G2)
0.2 (AWG 24)
2
Wire [mm
]
For power/grounding (U/V/W/
E)
2 (AWG 14)
For thermistor (G1/G2)
0.2 (AWG 24)