Sony 3-875-814-21(1) Operating Instructions Manual page 52

Sony multi channel av receiver operating instructions
Table of Contents

Advertisement

Checking the auto calibration
results
If a warning message or error code appears in
step 8 of "Performing auto calibration"
(page 48), check the problem of the error and
perform auto calibration again.
1
Press B/b to select "Yes," then
press
when "Error occurred
during calibration, press to
investigate." appears on the
screen.
Confirm the details of the measurement
results, then proceed with the appropriate
remedy.
Message list after auto calibration measurement
Display
Explanation
Code 30
Headphones are connected. Remove the headphones and perform the auto calibration again.
Code 31
SPEAKERS (OFF/A/B/A+B) is set to OFF. Set it to others and re-perform the measurement.
Code 32
None of the speakers were detected. Make sure that the optimizer microphone is connected
properly and reperform the measurement.
If the optimizer microphone is connected properly but the error code appears, the optimizer
microphone cable may be damaged or improperly connected.
Code 33
• None of the front speakers are connected or only one front speaker is connected.
• The optimizer microphone is not connected.
• Either the left or right surround speakers is not connected.
• Surround back speakers are connected even though surround speakers are not connected.
Connect the surround speaker(s) to the SURROUND terminals.
• The surround back speaker is connected only to the SURROUND BACK SPEAKERS R
terminals. When you connect only one surround back speaker, connect it to the
SURROUND BACK SPEAKERS L terminals.
Code 34
Speakers are not placed in the proper position. Speakers or an optimizer microphone on the
right or left may be placed wrongly. See "1: Installing speakers" (page 21) and check the
speaker position.
Warning 40
The measurement has completed. However, the noise level is high. You may be able to
perform the measurement properly if you try it again, even though the measurement cannot
be performed in all environments. Try to perform the measurement in a quiet environment.
Warning 41
The input from the microphone is too big.
Warning 42
• It may be too close the distance between the speaker and the microphone.
Retry the measurement after setting apart from each other.
• It may be that the volume is too big when you use the receiver as a preamp.
Warning 43
The distance and position of a subwoofer cannot be detected. Or the angle of the speaker
position cannot be detected. This may be caused by noise. Try to perform the measurement
in a quiet environment.
52
GB
2
Press B/b to select "Retry,"
then press
3
Repeat steps 6 to 8 in
"Performing auto calibration"
(page 48).
To save measurement results
that caused an error without
taking a remedy
1
Press B/b to select "No", then press
when "Error occurred during
calibration, press to investigate."
appears on the screen.
2
Follow the steps in "Saving the
measurement results" (page 51) to
save the measurement results.
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Str-da6400es