Sony 3-289-204-41(1) Operating Instructions Manual page 102

Sony multi channel av receiver operating instructions
Table of Contents

Advertisement

Performing Auto Calibration
For details on the Auto Calibration, see "9:
Calibrating the appropriate speaker settings
automatically (Auto Calibration)" (page 44).
Refer to "Before you perform the Auto
Calibration" (page 44) before performing the
Auto Calibration.
To operate on the receiver
1
Press GUI MODE repeatedly to select
"GUI OFF".
2
Press AMP.
Receiver operation is enabled.
3
Press MENU.
4
Press V/v repeatedly to select
"<AUTO CAL>" , then press
5
Press V/v repeatedly to select
"A.CAL START", then press
the measurement.
Measurement starts in 5 seconds. A count
down is displayed.
Note
While the time is counting down, stand away
from the measurement area to avoid
measurement error.
6
Measurement starts.
The measurement process will take
approximately 30 seconds. Wait until the
measurement process completes.
To cancel Auto Calibration
The measurement will be canceled when you
do the following:
– Press ?/1, input buttons or MUTING.
– Press SPEAKERS (OFF/A/B/A+B) on the
receiver.
– Change the volume level.
– Connect the headphones.
GB
102
Tips
• Operations other than turning the receiver on or off
are deactivated during Auto Calibration.
• The measurements may not be performed correctly
or Auto Calibration cannot be performed when
special speakers, such as dipole speakers are used.
To confirm/save Auto
Calibration when GUI function
is turned off
1
Confirm the measurement result.
When the measurement ends, a beep
sounds and the measurement result appears
on the display window.
Measurement
result
When the
measurement
process
.
completes
properly
to start
When the
measurement
process fails
2
Press V/v repeatedly to select the item,
then press
Item
RETRY
SAVE EXIT
WARN CHECK Displays a warning
PHASE INFO.
DIST. INFO.
LEVEL INFO.
Display
Explanation
window
COMPLETE Proceed to step
2.
E-
See "Message
xxx:xx
list after Auto
Calibration
measurement"
(page 49).
.
Explanation
Performs the Auto Calibration
again.
Saves the measurement
results and exits the setting
process.
concerning the measurement
results. See "Message list
after Auto Calibration
measurement" (page 49).
Displays the phase of each
speaker (in phase/out of
phase). See "When you select
"PHASE INFO."".
Displays the measurement
result for speaker distance.
Displays the measurement
result for speaker level.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Str-da2400es

Table of Contents