Mechanical And Electrical Principles - IBM 80 Customer Engineering Manual

Card sorting machine
Table of Contents

Advertisement

34
CARD
SORTING
MACHINE,
TYPE
80
of this key. The stop key, when depressed, renders the
runout feature of the machine inoperative and causes
immediate stopping of the machine.
Current, Weight, and Dimensions
The maximum operating current, starting current,
and fuse rating of the Type SO machine equipped with
a Y3 HP motor should be:
Voltage Group
Volts Cycles Phases
115
DC
230
DC
115
25
1
115
50
1
115
60
1
127
50
1
150
60
1
208
50
1
208
50
2
208
50
3
208
60
1
230
25
1
230
50
1
230
60
1
230
50
3
Weight unpacked
Weight packed
Length
Width
Height
Operating
Current
Amperes
4.1
2.3
5.2
5.5
5.3
5.0
4.3
3.8
2.8
2.4
3.6
2.9
3.0
2.9
2.1
Starting
Main
Current
Fuses
Amperes
Amperes
31.5
12
16.0
6
26.3
12
28.0
12
29.2
12
20.5
12
17.5
12
12.5
6
6.5
6
8.2
6
12.5
6
13.4
6
14.2
6
14.8
6
9.5
6
445 pounds
735 pounds
63 inches
16 inches
45 inches
MECHANICAL AND ELECTRICAL PRINCIPLES
THE MECHANICAL principles of the Type 80 Sorter
are identical to those of the Type S2.
The electrical principles of the Type 80 machine
differ somewhat from those employed in the Type 82.
No tubes are present in the Type SO machine; there-
fore, the use of a time delay relay to allow time for
tubes to heat up is not necessary. A high speed slate
base relay is employed in place of tubes to aid
In
controlling the energization of the sort magnet.
When a hole is sensed in the card, a circuit is com-
pleted to energize the sort magnet and cause pickup
of a high speed slate base relay. This circuit is con-
trolled through the card brush and the inner and outer
brushes on the commutator. Pickup of the high speed
relay closes its contact point and maintains a hold
circuit to the sort magnet through the center and outer
commutator brushes. This hold circuit continues until
slightly after the 12 position on the card has passed
under the reading brush, thus completing the sensing
of any holes in that column. As on the Type 82
machine, if two holes are present in a column sensed,
and rio provisions are made by means of the contact
bars on the commutator to suspend sorting of one
value, the card will sort according to the first value
sensed by the brush.

Advertisement