GDM-20SHT
•
DIAGNOSIS
The monitor is equipped with self diagnosis and failure indication. Indicators will blink when the monitor detects adjust- _
ment limit or a major failure.
~
CONVER
SHAPE
SIZE
CENTER
Power Save
Power
State
(Amber)
(Green)
Power ON
Normal
OFF
OFF
OFF
OFF
OFF
ON
NO. H Sync
Stand-by
OFF
OFF
OFF
OFF
ON
ON
NO. V Sync
Suspend
OFF
OFF
OFF
OFF
ON
ON
NO. H/V Sync
Active off
OFF
OFF
OFF
OFF
ON
OFF
Out of Range
Out of Range
OFF
OFF
OFF
OFF
ON
Fla,hing
H. Failure
Failure
OFF
OFF
OFF
ON
Flashing
Flashing
V. Failure
Failure
OFF
OFF
ON
OFF
Flashing
Flashing
IK Protector
Failure
OFF
ON
OFF
OFF
Flashing
Flashing
HV Protector
Failure
ON
OFF
OFF
OFF
Flashing
Flashing
-16 -