Sony MKE-9020M Installation Manual

Dme processor pack, multi format dme processor
Hide thumbs Also See for MKE-9020M:

Advertisement

Quick Links

DME PROCESSOR PACK
MVE-9000-C
MULTI FORMAT DME PROCESSOR
MVE-9000
HK-PSU04
MKE-9020M
MKE-9021M
MKE-9040M
INSTALLATION MANUAL
1st Edition

Advertisement

Table of Contents
loading

Summary of Contents for Sony MKE-9020M

  • Page 1 DME PROCESSOR PACK MVE-9000-C MULTI FORMAT DME PROCESSOR MVE-9000 HK-PSU04 MKE-9020M MKE-9021M MKE-9040M INSTALLATION MANUAL 1st Edition...
  • Page 2 Pour toute réparation faire appel à une personne compétente uniquement. MVE-9000 Serial No. 10001 and Higher HK-PSU04 Serial No. 10001 and Higher MKE-9020M Serial No. 10001 and Higher MKE-9021M Serial No. 10001 and Higher MKE-9040M Serial No. 10001 and Higher...
  • Page 3 For MVE-9000 Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
  • Page 5: Table Of Contents

    Manual Structure Purpose of this manual ... 2 Related manuals ... 2 Contents ... 2 Trademark ... 2 1. Installation 1-1. Operating Environment ... 1-1 1-2. Power Supply ... 1-1 1-2-1. Power Specifications ... 1-1 1-2-2. Recommended Power Cord ... 1-2 1-3.
  • Page 6: Manual Structure

    This manual describes the application and operation of MVE-9000-C system..Maintenance Manual (Available on request) This manual describes the detailed service information. If this manual is required, please contact your local Sony Sales Office/Service Center. This manual is organized by following sections.
  • Page 7: Installation

    1-1. Operating Environment Operating guaranteed temperature : Performance guaranteed temperature : +10 dC to +35 dC Operating humidity : (relative humidity) Storage temperature : Mass (when all options are installed) : Approx. 27 kg Prohibited locations for installation . Areas where the unit will be exposed do direct sunlight or any other strong lights.
  • Page 8: Recommended Power Cord

    1-2-2. Recommended Power Cord This unit does not come with a power cord. To get a power cord, please contact your local Sony Sales Office/Service Center. . Use the approved Power Cord (3-core mains lead)/ Appliance Connector/Plug with earthing-contacts that conforms to the safety regulations of each country if applicable.
  • Page 9: Installation Space (External Dimensions)

    1-3. Installation Space (External dimensions) MVE-9000 IM 144.5 115.5 115.5 Unit : mm...
  • Page 10: Installing The Options

    (refer to the following table) already installed in the MVE-9000, in accordance with the speci- fied system configuration. MVE-9000-C options Model name Board configuration Plug-in board MKE-9020M MVS Interface Board Set MKE-9021M Input/Output Board Set MKE-9040M DVP-24A board Advanced Effects Board...
  • Page 11 4. While the eject levers are kept open as shown in the illustration, insert the plug-in board into the board guide rails. Eject levers Name of option Name of board Slot on the front side MKE-9040M DVP-24A board 3, 4, 5, 6 *1 : The DVP-24A boards are assigned to the following channels in accordance with the slots to which the boards are inserted.
  • Page 12: Installing The Connector Board

    Store the removed blank panel in a safe location. B3 x 5 The following procedures vary with the options. In the case of other than MKE-9020M 2. Insert the connector board horizontally level and secure it with the two fixing screws.
  • Page 13: Installing The Hk-Psu04

    B3 x 5 6. Attach the connecting cable on the harness support. 7. Connect the connecting cable to the connector. 8. Secure the harness support to the cover panel using the two screws supplied with MKE-9020M. Connecting cable Harness support MVE-9000 IM 1-4-3.
  • Page 14: Rack Mounting

    1-5. Rack Mounting The MVE-9000 installs in a 19-inch standard rack. To mount the MVE-9000 in a rack, use the specified rack mount kit and follow the procedure described below. Specified rack mount kit : RMM-10 If a rack mount kit other than the specified one is used, the unit may not be correctly install in a 19-inch standard rack.
  • Page 15 3. Attach the right and left adaptors to the rack complete- ly using the specified six screws. (The illustration below shows the left adaptor.) B4 x 10 31.75 4. Tighten the screws (B4 x 6 : two screws each on the right and left) for adjusting the length of the adaptor completely (the screws that were loosened in step 2).
  • Page 16: Matching Connectors And Cables

    BELDEN 8281 coaxial cable D-sub 9-pin, Male Connector 9-pin, Male 1-560-651-00 Junction Shell 9-pin 1-561-749-00 D-sub 25-pin, Male Connector 25-pin, Male 1-560-904-11 Junction Shell 25-pin 1-563-377-11 Dedicated cable (Supplied accessory of MKE-9020M) BNC, 75 Z BELDEN 8281 coaxial cable MVE-9000 IM...
  • Page 17: Input/Output Signals Of Connectors

    1-7. Input/Output Signals of Connectors The input/output signals of the connectors at the rear panel are as follows. <CONTROLLER> indicates a controlling device. <DEVICE> indicates a controlled device. REMOTE 1-4 : RS-422A (D-sub 9-pin, Female) <DEVICE> (*1) _ EXT VIEW _ Pin No.
  • Page 18: Checks On Completion Of Installation

    1-8. Checks on Completion of Installation 1-8-1. On-board Switches Setting and LED Functions The number shown in parentheses ( ) indicates the address on the circuit board. 1. CA-54CFA board TP1301 S402 S401 D409 D410 D1303 D601 D1002 D1001 D602 D704 D1201 D701...
  • Page 19 D602 (A-2) : PLL LOCK status LED REF IN signal format status indication. Lit when the REF IN signal matches with the switcher format setup. D701 (A-2) : SBUS RX status LED S-BUS receive status indication. Lit while the data receive is in progress. D704 (A-2) : SBUS TX status LED S-BUS send status indication.
  • Page 20 <Connector> CN103 (A-4) : TERMINAL pin This pin is connected to the main CPU control terminal and used during maintenance. Conforms to RS-232C. CN401 (A-5) : TERMINAL pin This pin is connected to the IEEE1394 control terminal and used during maintenance. Conforms to IEEE1394.
  • Page 21 <LED on the CPU-DK module> : COM CPU-1 : COM CPU-2 DI1 (green) (B-5) : CD (Card Detect) status LED Lit when the CPU-DK module is inserted correctly to the parent board. DI2 (green) (F-3) : RUN status LED Lit when the CPU-DK module starts operating. DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) : STATUS1 to STATUS4 LED Used for maintenance purpose.
  • Page 22 TP9 (C-3) : PERR signal check terminal PERR signal measuring terminal. TP10 (C-3) : SERR signal check terminal SERR signal measuring terminal. TP11 (B-1) : PAR signal check terminal PAR signal measuring terminal. TP12 (D-1) : INT signal check terminal INT signal measuring terminal.
  • Page 23 2. DVP-24A board (MKE-9040M) TP601 TP201 E201 <LED> D501 (H-5) : + + + + + 1.5 V-1 +1.5 V-1 power supply status indication. Lit when the +1.5 V-1 power is supplied. D502 (H-5) : + + + + + 2.5 V-1 +2.5 V-1 power supply status indication.
  • Page 24 D3704 (H-2) : SYSTEM status LED Lit when configuration is complete and FPGA reset is also complete. If the LED does not light, the FPGA may be defective. D3705 (H-5) : CN EXIST status LED CN-2357 board presence/absence status indication. Lit on the DVP-24A board that is installed in the same slot of CN-2357 board when CN-2357 board is present.
  • Page 25 TP501 (H-5) : + + + + + 1.5 V-1 check terminal +1.5 V-1 measuring terminal. TP502 (H-5) : + + + + + 2.5 V-1 check terminal +2.5 V-1 measuring terminal. TP503 (H-5) : + + + + + 3.3 V check terminal +3.3 V measuring terminal.
  • Page 26 3. VIF-28 board E623 D601 TP201 TP601 D605 TP605 D604 TP604 D602 TP602 D603 TP603 E608 TP3105 TP3104 TP3102 TP3103 CN3202 E606 CN3203 S3201 CN4001 E604 D3304 D3302 D3303 D3301 D3401 D3402 D3403 D3404 CPU-DR ND3401 ND3402 Module E607 TP3401 TP3404 TP3402 TP3403 S3401...
  • Page 27 D3401, D3402, D3403, D3404 (A-10) : DBG7-4 Used for design purpose. ND3401 (A-10), ND3402 (A-11) : STATUS LED VIF-28 board CPU status indication. <Switches> S3201 (A-8) : CPU CONFIG switch Used for maintenance purpose. S3401 (A-10) : SETUP switch Used for maintenance purpose. <Connectors>...
  • Page 28: System Connection

    1-9. System Connection Connection Example of the MVS-8000 System (MKE-9020M Installed) Ethernet switch Ethernet switch Reference video signal DATA CTRL REMOTE 1 MVS-8400/8300/8200 Switcher Processor Pack a) It is recommended that the CTRL and DATA LAN networks be configured by connecting separate Ethernet switches for each LAN.
  • Page 29 Flow of Video Signals (MKE-9020M Installed) The figure below shows the flow of video signals in a MVS-8000 system. SWITCHER A SWITCHER B DME 1B DME 1A PRIMARY INPUTS 1-68 PRIMARY INPUTS 69-80 For the AC power cord of this unit, refer to Section 1-2 “Power Supply”...
  • Page 30 Connection Example of the MVS-8000 System (MKE-9021M Installed) Ethernet switch Ethernet switch Reference video signal DATA CTRL REMOTE 1 MVS-8400/8300/8200 Switcher Processor Pack a) It is recommended that the CTRL and DATA LAN networks be configured by connecting separate Ethernet switches for each LAN. However, it is also possible to make connections for both LANs on a single Ethernet switch.
  • Page 31 Flow of Video Signals (MKE-9021M Installed) The figure below shows the flow of video signals in a MVS-8000 system. V. K IN/EXT IN OUTPUTS 1-48 MONITOR OUTPUTS Monitor For the AC power cord of this unit, refer to Section 1-2 “Power Supply”...
  • Page 33: Service Overview

    2-1. Troubleshooting The main power cannot be turned on. (Indicator does not light green.) Flow1 The main power of the MVE-9000 cannot be turned on. (Indicator does not light green.) Is the POWER switch A of the MVE-9000 turned ON? Is the power cord of the MVE-9000 connected correctly? The power supply unit is probably defective.
  • Page 34: Periodic Inspection And Maintenance

    This may have an adverse effect on performance and the life of the machine. Cleaning of the fan every month is recommended. Contact your local Sony Sales Office/Service Center for information on cleaning the fan. 2-3. About the Data Backup Capacitor...
  • Page 35 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 36 Printed in Japan Sony Corporation MVE-9000-C (SY) E 2003. 4 08 B&P Company 3-790-017-01 ©2003...

This manual is also suitable for:

Mve-9000Mve-9000-cHk-psu04Mke-9021mMke-9040m

Table of Contents