Service Overview; Troubleshooting - Sony HK-PSU02 Installation Manual

Multi format dme processor pack
Hide thumbs Also See for HK-PSU02:
Table of Contents

Advertisement

2-1. Troubleshooting

The main power cannot be turned on. (Indicator does not light green.)
Flow1
The main power of the MVE-8000A cannot be turned on.
(Indicator does not light green.)
YES
Is the POWER switch A of the MVE-8000A turned ON?
YES
Is the power cord of the MVE-8000A connected correctly?
YES
The power supply unit is probably defective.
The monitor picture is not displayed correctly.
Flow2
The monitor picture is not displayed correctly even
though the main power of the MVE-8000A is turned on.
YES
Are the plug-in boards inserted into their correct slots?
YES
Are the option boards inserted into their correct slots?
YES
Are the input and output cables connected correctly?
YES
Is the software installed correctly?
YES
Is the system set in the Factory Set mode?
YES
The MVE-8000A is probably defective.
MVE-8000A
Section 2

Service Overview

NO
Set it to ON.
NO
Connect it correctly.
NO
Insert the plug-in boards into the correct slots.
(Refer to the MVE-8000A-C Maintenance Manual.)
Insert the option boards into the correct slots
NO
respectively. (Refer to Section 1-4.)
NO
Connect the input and output cables and equipment
correctly.
NO
Install the software correctly.
(Refer to the User s Guide.)
NO
Start up the system in the Factory Set mode and
check to see.
* About the Factory Set, refer to Chapter Engineering Setup
of the MVS-8000 System User s Guide.
2-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mke-8020aMve-8000a-cMve-8000aMke-8040a

Table of Contents