Apera Instruments ORP60-Z Instruction Manual

Apera Instruments ORP60-Z Instruction Manual

Smart orp/redox tester, orp/temp.

Advertisement

Quick Links

SKU:AI3717
ORP60-Z Smart ORP/Redox Tester
(
ORP/Temp.)
Instruction Manual
APERA INSTRUMENTS, LLC
www.aperainst.com
V1.03
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ORP60-Z and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Apera Instruments ORP60-Z

  • Page 1: Instruction Manual

    SKU:AI3717 ORP60-Z Smart ORP/Redox Tester ORP/Temp.) Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com V1.03 - 1 -...
  • Page 2: Table Of Contents

    Contents Introduction - 3 - Battery Installation - 4 - Keypad Functions - 4 - Complete Kit - 5 - Things to Know Before Use - 5 - ORP Measurement - 5 - ORP Calibration - 6 - Parameter Setting - 7 - Technical Specifications - 8 -...
  • Page 3: Introduction

    Int rodu ct ion Dear Customer, Thank you for choosing Apera Instruments ORP60-Z Smart ORP Tester. Please carefully read this manual before using the product in order to have a reliable testing experience. 1.1 This product is designed with a two-way control on both the tester and ZenTest Mobile App. Please refer to the functions available on each platform in the following table.
  • Page 4: Battery Installation

    Bat t e r y I nst a ll at i on Please install batteries according to the following steps. *Please note direction of batteries: All POSITIVE SIDES (“+”) FACING UP. (Wrong installation of batteries will cause damage to the tester and potential hazards) ①...
  • Page 5: Complete Kit

    Co mpl et e Kit Graph-2 T hings to Know Bef o re U s e A few drops of water are added to the probe cap to keep the pH electrode in an activated state before the tester leaves factory. Generally, users can start using the tester directly. If the measuring response is slow, users can soak the ORP electrode for 30 minutes in the 3M KCL storage solution (fill to the fill-line) before using it;...
  • Page 6: Orp Calibration

    O R P C al ib r at io n 7.1 Pour some 222 mV ORP standard solution into the calibration bottle (to about half volume). 7.2 Rinse electrode in distilled water and dry it. Short press to turn the meter on. Long press to enter calibration mode.
  • Page 7: Parameter Setting

    The Maintenance of ORP Probes After long-time use, the surface of the platinum pin can be contaminated and cause inaccuracy or slow response time. If that happened, the following methods can be adopted to clean and re-activate the sensor: For contamination caused by inorganic substances, dip the probe into 0.1 mol/L dilute hydrochloric acid for 30 minutes.
  • Page 8: Technical Specifications

    APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS (SIX MONTHS for the probe) from the delivery. This limited warranty does NOT cover any damages due to: accidental damage, unauthorized repair, normal wear and tear, or external causes such as accidents, abuse, or other actions or events beyond our reasonable control.

This manual is also suitable for:

Ai3717

Table of Contents