SOLIDS INTERCEPTORS
Z1182 SOLIDS INTERCEPTOR – OPERATION and MAINTENANCE INSTRUCTIONS
SIZING
The Z1182 side access stainless steel solids interceptor is designed
for suspended or under sink installations where there are height
restrictions for a top removal solids interceptor. This unit is furnished
with a 2" [51 mm] no-hub high inlet and low outlet on each side for
left-hand or right-hand installation. (Note: Cap the side not used.) The
interceptor is capable of handling a maximum flow rate of 35 GPM.
DESIGN
The Zurn Z1182 Solids Interceptor is designed to recover food waste
from sinks, garbage grinders, and dishwashers. This is accomplished
through the principal of screening. The food wastes are retained in
the inlet side of the unit by a perforated removable drawer.
OPERATION
The wastewater flows from the inlet piping into the interceptor, passing
through the perforated drawer attached to the gasketed latching cover,
then exits the interceptor to the sanitary drain system. The waste
material is trapped in the perforated drawer and not allowed to pass
through to the outlet piping of the drain system.
MAINTENANCE
Cleaning should be done on a regular basis, either before or after the
perforated drawer becomes clogged. Remove the drawer and clean
out all debris. Hose off the drawer screen. Make certain the sealing
gasket is intact and clean. Apply a light coating of oil on the gasket,
Z1183 SOLIDS INTERCEPTOR – OPERATION and MAINTENANCE INSTRUCTIONS
SIZING
The sizing of this interceptor relates to the size of the Z1170 grease
interceptor it is being used with. All units are made with a standard
no-hub pipe size inlet and outlet, and are capable of handling drainage
volumes standard to their respective pipe size.
DESIGN
The Zurn Z1183 Solids Interceptor is designed to recover food waste
from sinks, garbage grinders, and dishwashers. This is accomplished
through the principal of gravity separation. The food wastes are retained
in the perforated removable basket.
OPERATION
The wastewater flows from the inlet piping into the removable perforated
basket, passing through the basket and the outlet cover screen attached
to the cover, into the main body chamber, then exits the interceptor to
the sanitary drain system.
MAINTENANCE
Cleaning should be done on a regular basis, either before or after the
basket or outlet screen becomes clogged. Remove the cover and basket
and clean out all debris. Hose off the outlet cover screen. Replace the
basket into the interceptor. Make certain cover gasket is intact and
clean. Apply a light coating of oil on the cover gasket, which helps
prevent the cover gasket from adhering to the body and aids in
ZURN PLUMBING PRODUCTS GROUP SPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com
which helps prevent the gasket from adhering to the drawer and
aids in maintaining a complete seal. The perforated drawer should
then be placed back in the unit and secured. Efficiency of operation
is directly related to the level of maintenance.
maintaining a complete seal. The cover should then be placed back
on the unit and secured. Efficiency of operation is directly related to
the level of maintenance.