Troubleshooting - Bissell 9200 SERIES User Manual

Bissell user's guide vacuum cleaner 9400 series, 9200 series
Hide thumbs Also See for 9200 SERIES:
Table of Contents

Advertisement

T
roubleshooting
Built-in heater ready light does not illuminate
Possible Cause
1. The heater switch is not turned ON ( I ).
2. The power switch is not turned ON ( I ).
Reduced spray or no spray.
Possible Cause
1. 2-in-1 water tank may be empty.
2. Formula tank may be empty.
3. 2-in-1 water tank may not be
seated completely.
4. Pump may have lost prime.
DirtLifter PowerBrushes do not turn
Possible Cause
1. The brush is off or broken.
2. The unit is in the upright position.
3.
Circuit breaker may have tripped.
Scotchgard protector applicator tool is not spraying
Possible Cause
1. Cartridge is not connected to the tool.
2. Ready Tools dial on floor setting.
3.
Formula clogging the spray trigger.
w w w . b i s s e l l . c o m
ug310-5880_9200E_406.indd 19
ug310-5880_9200E_406.indd 19
WARNING:
To reduce the risk of fire,
electric shock or injury
unplug from the outlet
before servicing.
Remedies
1. Turn the heater switch ON ( I ).
2. Both switches must be ON ( I ) to
activate the heater ready light.
Remedies
1. Fill heavy duty bladder with hand hot
tap water.
2. Fill formula tank with BISSELL Deep
Cleaning Formula for cleaning.
3. Turn power switch OFF ( O ).
remove and reseat 2-in-1 water tank.
4. Turn power switch OFF ( O ) and
then back ON ( I ). Wait one minute,
then depress spray trigger.
Remedies
1. Turn power switch OFF ( O ) and
unplug unit from outlet. Follow
instructions on page 17.
2. Brushes only rotate when unit is
reclined using the detent pedal .
3.
Turn the power switch OFF ( O ) and
unplug from outlet. Check to see if
foreign object is caught in brush roll.
remove object. Plug machine back in
to reset circuit breaker .
Remedies
1. Follow instructions on cartridge to
assure proper fit.
2. Set Ready Tools dial to hose
attachments setting .
3.
Soak applicator tool only in hand hot
water. Spray without the cartridge
attached to purge any residual
formula left in the applicator tool .