Specifications - Panasonic HG-S Series Instruction Manual

Contact-type digital displacement sensor / sensor head
Hide thumbs Also See for HG-S Series:

Advertisement

5

SPECIFICATIONS

General purpose
Type
Standard type
Model No.
HG-S1010
Position detection method
Measurement range (Note 2)
Stroke (Note 2)
Downward
1.65N or less
mount
1.1N (Note 3)
Measur-
1.35N or less
Upward mount
ing force
0.85N (Note 3)
1.5N or less
Side mount
0.95N (Note 3)
Resolution
• Full range: 2.0µm or less
Indication accuracy (P-P)
• Limited range: 1.0µm or less (any 60µm)
Hot swap function
Protective structure
IP67 (IEC) (Note 5)
Ambient temperature
-10 to +55°C (No dew condensation or icing allowed), Storage: -20 to +60°C
Ambient humidity
Mechanical life (Note 6)
Tip deviation amount
Grounding method
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel
Material
Probe: Ceramic, Rubber bellows: NBR (black)
Weight (main unit only)
Notes: 1) Measured at an ambient temperature of +20°C, unless otherwise specified.
2) 5 to 10mm range when HG-S□R is mounted in upward mount.
3) Typical value near center of measurement.
4) Standard state without the rubber bellows.
5) Excludes damage and deterioration to the rubber bellows due to external causes.
6) Typical value in a clean environment in which there is no contact with liquids such as water or oil, and no set-
tling of particulate matter.
When the HG-S□R is installed in the upward orientation, 4 million times (typical value).
6
CAUTIONS
The special sensor head HG-S□ is designed to be used with the controller
HG-SC□. If used with other than the special sensor head option, the specifications
will not be met and product malfunctioning or damage may occur.
● This device has been developed / produced for industrial use only.
● D o not use this product outside the range of the specifications. Risk of an accident
and product damage. There is also a risk of a noticeable reduction of service life.
● Deviations may occur in the measured value at the bottom dead point. Do not use
the bottom dead point as a standard.
● Do not wire in parallel with a high-voltage line or power line, or run through the
same conduit. Risk malfunctioning due to induction.
● Verify that the supply voltage fluctuations are within the rating.
● If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
● Do not use during the initial transient time after the power supply is switched ON.
● Do not apply stress such as excessive bending or pulling to the extracted part of a cable.
● This product is suitable for indoor use only.
● Avoid dust, dirt, and steam.
● Do not use this sensor in places where it may come in contact with corrosive gas, etc.
● Ensure that the product does not come into contact with organic solvents such as thinner.
● Ensure that the product does not come into contact with strong acid or alkaline.
● Ensure that the product does not come into contact with oil or grease.
● This product cannot be used in an environment containing flammable or explosive gases.
● Performance may not be satisfactory in a strong electromagnetic field.
● This product is a precision device. Do not drop or otherwise subject to shock. Risk
of product damage.
● Never remove the standard rubber bellows except for replacement.
Risk of product damage due to infiltration by dust, water, or other contaminants.
● When the product becomes unusable or unneeded, dispose of the product appro-
priately as industrial waste.
● Never attempt to disassemble, repair, or modify the product.
7
MAINTENANCE
How to replace the probe
● Always secure the spindle to prevent rotation before replacing the probe. Risk of
product damage if an excessive torque (0.2N·m or more) is applied to the spindle.
● If the rubber bellows is damaged or deformed during probe replacement, the
specifications of the protective structure may not be satisfied.
1. Turn the probe screw in the direction of the arrow and remove the probe from the
spindle. When turning the probe screw, hold the cut face of the spindle with the
provided sensor head fastening wrench to prevent the spindle from turning.
Hold the sensor head fastening wrench in place, and turn only the probe.
Sensor head
fastening wrench
(Accessory)
2. Attach the new probe to the spindle. The tightening torque
should be 0.4N·m or less. Make sure that the probe does
not come OFF.
When turning the probe screw, hold the cut face of the
spindle with the provided sensor head fastening wrench to
prevent the spindle from turning.
Hold the sensor head fastening wrench in place, and turn
only the probe.
3. After attaching the probe, wipe the spindle with absolute alcohol to remove any dirt.
High precision
Low measuring
Standard type
force type
HG-S1010R
HG-S1110
Optical absolute linear encoder method
10mm
10.5mm or more
0.35N or less (Note 4)
1.65N or less
0.35N or less (Note 4)
0.3N (Note 3, 4)
1.1N (Note 3)
0.12N or less (Note 4)
1.35N or less
0.12N or less (Note 4)
0.05N (Note 3, 4)
0.85N (Note3)
0.25N or less (Note 4)
1.5N or less
0.25N or less (Note 4)
0.2N (Note 3, 4)
0.95N (Note 3)
0.5µm
0.1µm
• Full range: 1.0µm or less
• Limited range: 0.5µm or less (any 60µm)
Incorporated
-
IP67 (IEC) (Note 5)
35 to 85% RH, Storage: 35 to 85% RH
100 million times or more (reference value)
35µm (typical value)
Capacitor grounding
Approx. 80g
How to replace the rubber bellows
● When replacing the rubber bellows, take care that no dirt or other contaminants
Low measuring
get on the spindle. Risk of malfunctioning. If any dirt gets on the spindle, wipe
force type
clean with absolute alcohol. Do not allow the rubber bellows to become twisted
HG-S1110R
during attachment.
● Note that the measuring force will vary depending on the attachment state of the
rubber bellows.
● If the rubber bellows is deformed, a load will occur when the spindle operates
and damage may result.
0.3N (Note 3, 4)
1. Turn the probe screw in the direction of the arrow and remove the probe from the
0.05N (Note 3, 4)
spindle. When turning the probe screw, hold the cut face of the spindle with the
provided sensor head fastening wrench to prevent the spindle from turning.
0.2N (Note 3, 4)
Hold the sensor head fastening wrench in place, and turn only the probe.
Sensor head
fastening wrench
-
(Accessory)
2. Remove the rubber bellows from the spindle.
3. Fit the new rubber bellows onto the spindle.
Insert to the top edge of the spindle as
shown at right.
4. P ush the rubber bellows up with your finger
until the tip of the spindle is exposed as
shown at right.
5. Attach the probe to the spindle. The tighten-
ing torque should be 0.4N·m or less. Make
sure that the probe does not come OFF.
When turning the probe screw, hold the cut
face of the spindle with the provided sensor
head fastening wrench to prevent the spindle
from turning.
Hold the sensor head fastening wrench in
place, and turn only the probe.
6. Make sure that the rubber bellows has not
become deformed as shown at right.
If the rubber bellows is deformed, restore the
normal shape by rotating the bellows or oth-
erwise.
Probe
Turn
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
Turn
For sales network, please visit our website.
PRINTED IN JAPAN
Probe
Turn
Rubber bellows (Option)
Insert to top edge
Spindle tip
Turn
© Panasonic Industrial Devices SUNX Co., Ltd. 2015