Download Print this page

Bosch Rexroth H-4WEH...XE Series Operating Instructions Manual page 31

4/2 and 4/3 directional valves, internally pilot-operated, externally pilot-operated
Hide thumbs

Advertisement

Fig. 4: Cable and line entry
1
O-ring
2
Double nipple
3
Seal insert
4
Screw-in bushing
5
Clamping screws of the pull relief
In the state as delivered, the cable and line entry is already screwed in the
terminal box of the valve.
1.
De-energize the relevant system part.
2.
Open the terminal box (internal hexagon, wrench size 3).
3.
Remove the outer sheath of the connection line and the insulation of the
individual conductors. Press the wire end ferrule on the individual conductors.
For the stripping lengths, refer to fig. 5 and table 14.
Fig. 5: Stripping lengths
5
L1
L2
RE 24751-XE-B/04.16, H-4WEH...XE..., Bosch Rexroth AG
Assembly
1
2
3
4
L4
L3
31/52