Introduction; System Descriptions; Self Contained Systems; Chilled Water Models - Emerson Liebert Challenger 3000 Installation Manual

Precision cooling for business-critical continuity, 3 & 5 tons, 50 & 60hz
Hide thumbs Also See for Liebert Challenger 3000:
Table of Contents

Advertisement

1.0
I
NTRODUCTION
1.1

System Descriptions

Challenger 3000
• self contained system with a scroll compressor in the room unit
• self contained chilled water system
• split system with an evaporator section and a remote condensing unit
All three types are available in upflow or downflow configurations. The standard upflow configuration
is front return. All models require three-phase power. Units are available in 208, 230, 460, or 575 V,
60 Hz; and 200, 230 or 380/415 V, 50 Hz.
The following features are included as standard in all room units regardless of the type of system:
A-frame coil (V-frame on upflows), infrared humidifier, finned tubular stainless steel electric reheat,
2" filter, individual high voltage fused protection, and fan assembly.
Each configuration can operate with either Advanced Microprocessor Controls (A), or Advanced
Microprocessor Controls with Graphics (G). A brief description of each, including operational differ-
ences, is listed below. Check model numbers to see what is supplied with your unit.
1.1.1

Self Contained Systems

Air Cooled Models
Complete refrigeration system including hot gas bypass and crankcase heater with standard con-
denser and fan speed control for 95°F (35°C) ambient at sea level.
Water Cooled Models
Compete refrigeration system including hot gas bypass with water/glycol cooled condenser and two-
way water regulating valve with bypass.
Glycol Cooled Models
The water cooled model as described above plus pump package and 95°F (35°C) design ambient dry-
cooler.
GLYCOOL Models (5 Ton Only)
Complete refrigeration system including hot gas bypass with glycol condenser and three-way water reg-
ulating valve plus an integrally piped Econ-O-Coil with three-way modulating control valve.
1.1.2

Chilled Water Models

Chilled Water models include chilled water piping, three-way modulating valve, and actuator assem-
bly.
1.1.3

Split Systems

Each Air Cooled split system consists of an evaporator section and one of the following condensing
units.
Prop Fan
Includes scroll compressor, condenser coil, prop fan, high pressure switch, and Lee-Temp head pres-
sure control. Unit is designed for outdoor location.
Centrifugal Fan
Includes scroll compressor, condenser coil, centrifugal blower assembly, high pressure switch, head
pressure control valve, Lee-Temp receiver and liquid line solenoid valve. Unit must be mounted
indoors. Duct flanges are optional.
Each Water Cooled split system consists of an evaporator section and a water/glycol condensing unit,
which includes scroll compressor, coaxial condenser, water regulating valve, and high pressure switch.
Design pressure is 150 psi (1034 kPa) as standard and 350 psi (2413 kPa) as optional.
Each Glycol Cooled split system consists of an evaporator section, a water/glycol condensing unit (as
described above), a pump package, and a 95°F (35°C) design ambient drycooler.
environmental control systems are available in three main system configurations: