Usersetcontrol; Counterandtimercontrol - Dahua 3000 Series User Manual

Usb3.0 area scan industrial camera
Table of Contents

Advertisement

5.8

UserSetControl

In this property, you can save or load the parameter scheme set by user and set the default parameter
configuration when opening the client, as shown in Figure 5-8; please refer to Sheet 5-9 for detailed
parameter settings.
Parameter
UserSetSelector
UserSetLoad
UserSetSave
UserSetDefault
UserSetLoadLastUserSet
UserSetLoadStatus
5.9

CounterAndTimerControl

In this property, the counter can divide the frequency of the external input trigger signal and execute
exposure control according to the user's logic, as shown in Figure 5-9; please refer to Sheet 5-10 for
detailed parameter settings.
Please set TriggerSource in 5.3 AcquisitionControl before using.
Figure 5-8 User Set Control
Sheet 5-9 User Set Control - Parameter Explanation
Explanation
UserSetSelector: supports Default, UserSet1 and UserSet2.
Selects which series to use for the subsequent UserSetLoad and UserSetSave
operation.
UserSetLoad: restores the camera configuration to the configuration that user
selected.
UserSetSave: saves the current configuration to the selected series, but the
Default series does not support saving.
Default user set when the power is on. UserSet1 and UserSet2 need to
execute UserSetSave before display.
The last user configuration the user used.
User set load status.
Displays whether the configuration has been successfully loaded.
Main Function Description