BBV Rx100/24 Supply Additional information
The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that
should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be
at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections
made to L and N. The 24Vac supply must be fused with a 315mA to protect the supply wiring.
Fig 9. RX100/24 iss. 6 pcb Connection details when operating from a 230Vac supply.
230Vac Supply
Fig 10. RX100/24 iss. 6 pcb Connection details when operating from a 24Vac supply.
IMPORTANT! Remove fuse from fuseholder
!
and make no connection as these terminals
will have 230Vac across L and N.