Installation - LG LWC1260ACG Owner's Manual

Table of Contents

Advertisement

INSTALLATION

If a power plug is not to be used, provide a circuit breaker between power source and the unit as
shown below.
BASE PAN
1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit.
If the unit receives direct sunlight, build an awning to shade the cabinet.
3. There should be no obstacle, like a fence, within 50cm which might restrict heat radiation from the
condenser.
4. Install the unit a little obliquely outward not to leak the condensed water into the room (about
10mm)
5. Install the unit with its bottom portion 70-150cm above the floor level.
6. The power cord must be connected to an independent circuit. The green wire must be grounded.
7. Connect the drain tube to the base pan hole.
Plastic hose or equivalent may be connected to the drain tube.
NOTE
Before installing the Air Conditioner back into the case, remove the white styrofoam shipping block
from the compressor.
COOLED AIR
DRAIN TUBE
Main power source
Circuit Breaker
Use a circuit breaker or time
delay fuse.
AWNING
HEAT RADIATION
ABOUT 10mm
OVER 50cm
Remove white
styrofoam block.
ENGLISH
FENCE
11