Fujitsu ASYG07-09-12KPCA Operating Manual

Fujitsu ASYG07-09-12KPCA Operating Manual

Air conditioner (wall mounted type)

Advertisement

OPERATING MANUAL
AIR CONDITIONER (Wall Mounted type)
MODEL:
*Please write down the model name.
(Refer to the rating label.)
Before using this product, read these instructions thoroughly
and keep this manual for future reference.
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. NAME OF PARTS ..................................................... 2
2.1. Remote controller ............................................... 2
2.2. Indoor unit ........................................................... 4
3. BASIC OPERATIONS ............................................... 4
4. AIRFLOW SETTINGS ............................................... 4
4.1. Fan speed setting ............................................... 4
4.2. Airfl ow direction setting ....................................... 4
5. TIMER OPERATIONS ............................................... 5
5.1. On timer or Off timer ........................................... 5
5.2. Program timer ..................................................... 5
5.3. Sleep timer ........................................................ 5
6. ENERGY SAVING OPERATIONS ............................ 5
6.1. Economy operation ............................................. 5
7. OTHER OPERATIONS ............................................. 5
7.1. Powerful operation .............................................. 5
8. CLEANING AND CARE ............................................. 5
9. GENERAL INFORMATION ....................................... 6
10. OPTIONAL PARTS ................................................... 7
10.1. Wireless LAN control ........................................ 7
11. TROUBLESHOOTING .............................................. 8
PART No. 9333892009

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classifi ed
as follows:
This mark warns of death or serious injury.
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor
unit.
WARNING
This symbol shows that this product uses a fl ammable
refrigerant. If the refrigerant is leaked and exposed to
an external ignition source, there is a risk of fi re.
CAUTION
This symbol shows that the operating manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operating manual or installation manual.
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or fi re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.
• In the event of refrigerant leakage, be sure to keep
away from fi re or any fl ammables, and consult
authorized service personnel.
• In the event of a thunder storm or any prior sign
of a lightning strike, turn off the air conditioner via
the remote controller, and refrain from touching the
product or the power source to prevent any electrical
hazards.
• This product shall be stored in a room without
continuously operating ignition sources (for example:
open fl ames, an operating gas appliance or an
operating electric heater).
• This product shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
En-1
WARNING
CAUTION
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASYG07-09-12KPCA

  • Page 1: Table Of Contents

    OPERATING MANUAL 1. SAFETY PRECAUTIONS AIR CONDITIONER (Wall Mounted type) To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi...
  • Page 2: Name Of Parts

    WARNING CAUTION • This product shall be stored so as to prevent • Do not use this product for preservation of food, plants, mechanical damage from occurring. animals, precision equipment, art work, or other objects. • Disposing of the product shall be done properly, in This may cause quality deterioration of those items.
  • Page 3 : The setting must be done while the setting screen is Remote controller display displayed for each function. In this section, all the possible indicators are displayed for : The button is controllable only when the air conditioner is description. In actual operation, the display is linked with the operating.
  • Page 4: Indoor Unit

    NOTES: 2.2. Indoor unit • In the Cooling or Dry mode, set the temperature lower than the current room temperature. • In the Cooling mode, the indoor unit fan may stop from time to time : The instruction is relating to the wireless LAN control (optional). to perform Fan control for energy saving that enables power-saving For Manual Auto operation operation by stopping the rotation of the indoor unit fan when the...
  • Page 5: Timer Operations

    5. TIMER OPERATIONS 6. ENERGY SAVING OPERATIONS NOTES: When [ ] indicator on the indoor unit blinks, set the clock 6.1. Economy operation and timer again. This blinking shows that the internal clock go wrong due to an interruption of the power supply. (Refer to page 7.) It saves more electricity than other operation modes by changing the set temperature to a moderate setting.
  • Page 6: General Information

    Intake grille Removing and installing intake grille Air fi lter ■ Removing intake grille 1. Open the intake grille. Indoor unit body 2. While pressing the left and right mounting shafts outward gently, pull the intake grille. The frequency of the cleaning is as shown in the following table. What to do Frequency Cleaning indoor unit body...
  • Page 7: Optional Parts

    ■ Automatic defrosting operation Google Play is a registered trademark of Google Inc. App store is a service mark of Apple Inc., registered in the U.S. and When outdoor temperature is very low with high humidity, frost may other countries. form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product.
  • Page 8: Troubleshooting

    • To control 2 or more air conditioners with the same smartphone or 11. TROUBLESHOOTING tablet PC, repeat the setup of the chosen mode. Register the air conditioner by following the instructions in the online manual on FUJITSU GENERAL web site. WARNING In the following events, immediately stop operation of www.fujitsu-general.com/global/support/ the air conditioner, and disconnect all the power supply by turning off...
  • Page 9 ■ State of indicator lamps □ <In the Heating mode> Is [ ] indicator blinking? : The instruction is relating to the wireless LAN control In this case, the Automatic defrosting operation is working. The in- door unit stops for maximum of 15 minutes. (Refer to page 7.) (optional).

Table of Contents