PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13 Suite 8 Southpoint Business Park Jupiter Ensign way FL-33458 Hampshire / Southampton United Kingdom, SO31 4RF From outside US: +1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0...
1.Introduction Thank you for purchasing this IR Meter Printer This unit has been developed to meet your maximum satisfaction with its user-friendly design.Please review the entire manual for a complete overview of how to operate this new IR Meter Printer 2.Material Supplied Check for damaged or missing parts in your IR Meter Printer before starting.
Temperature Range -40 ~ 500 Resolution 0.1 unit (<100 ) or 1 unit; Unit is or . Accuracy +/- 3% or 3 (Whichever is greater) Repeatability +/- 1 Emissivity Adjustable from 0.3 ~ 1.0 Response time 0.2 seconds Backlight / Laser sighting Yes / Yes Distance Ratio Printer...
Procedure capacity: 4 procedures in total. Indicated as #1 to #4 with procedure name. Measure point: 99 measure points in each procedure. Measure point content Each measure point consists of point number point name and temperature value. 3.3Datalogger Function Data logger capacity 4 data logger settings. Indicated by #5 to #8 Data logger setting Setting by Begin Date End Date Start Time Suspend Time Rate **.99 measure points in each data logger setting Measure point Each measure point consists of point number point title and...
if user doesn't key-in any. The name is consisted by current date and time. For example if point name is "05-06 09:21:51" means the date is 6th May and the time is 09:21:51. Note 2: Meter automatic defines the name of the measured point by current date and time.
6.Paper Replacement For feed paper and confirming setting. Feed the paper when it's held down except printing. Please follow the pictures to scissor out a paragraph from supplied printing paper To make easier feeding the paper insert the sharp-cut to the cartidge of the printer.
Page 8
Replacement When seeing the battery symbol flashing on the right-up corner of the LCD means the batteries are weak. If the power is too low to operate the IR printer, printer will reset with below indication on LCD monitor. Follow the steps to remove and replace batteries 1.
8.FUNCTION-IR thermometer with laser targeting 1.Press "ON" key to enter IR mode. LCD will display real-time target temperature until "ON" key released. After releasing the "ON" key, LCD will hold the last value for 10 seconds and then auto power off. 2.Press "ON"...
6.Press "PRINT" to print out procedure saved data "Print?" will appear on LCD If OK press "PRINT" again to continue If NO press "PROC" to back to procedure function. Please refer to below for the printed out data. 7.How to delete data Press "PROC"...
Page 11
Begin means begin date MM-DD-YY or DD-MM-YY or YY-MM-DD it depended on what is the date mode set in "SET" function. End means end date,same as above. Start means start time,HH/MM/SS Suspend means stop time,HH/MM/SS Rate means the time period to get the data.For example "60" means to get the value every 60 seconds.The rate could be from 1 to 9999.
Page 12
7.Press "PRINT" to print out data logger data "Print?" will appear on LCD If OK press "PRINT" again to continue If NO press "LOG" to back to data logger function Press "0" to stop printing Please be reminded that while data logger is still in recording status all the other functions of the meter could not be activated.
1.Press "SET" key to enter setting mode while meter is at IR mode. 2.Parameters could be set by users including LCD contrast( 1to 9 bright to dark) Print contrast(1to 9 light to heavy ) Emissivity Unit( or ) Date mode(MM-DD-YY or DD-MM-YY or YY-MM-DD pressing "ENTER"...
Need help?
Do you have a question about the PCE-JR 911 and is the answer not in the manual?
Questions and answers