I/O Module and Fieldbus Capacity

Table 12a. I/O Unit definition table
1 Chassis-mounted "Series A" I/O Module (
1 Rail-mounted "Series A or H" I/O Module
1 Serial Interface Module (SIM) FTA
1 Pulse Input Module (PIM)
1 FF Linking Device (FF LD)
1 non-redundant Fieldbus Interface Module (FIM)
1 Redundant Fieldbus Interface Module Pair (Red-FIM)
1 non-redundant or redundant PM IOP Module
1 DHRIO Module
1 1203-CN1 SCANport module for AB Drive Controller
1 SST-PFB-CLX Profibus Module
1 DeviceNet Bridge Module (DNB)
1 Source or Destination partner on Auxiliary Exchange peer to peer
Ethernet network
Table 12b. I/O Module and Fieldbus Capacity
I/O module Capacity per C200/CPM
Maximum number of I/O ControlNet CNI's per Controller Chassis ("Downlink CNI")
Maximum number of I/O Units per C200/CPM
(See above for I/O Unit definition)
Maximum number of I/O Units per downlink ControlNet CNI
(See above for I/O Unit definition)
Maximum number of Serial Interface Modules per C200/CPM
Maximum number of FTA assemblies per Serial Interface Module
Each SIM FTA is the equivalent of 4 IO UNITS in the 64 IO per CPM calculation and the 24
IO per CNI calculation. See the IO UNIT Definition Table for details.
Maximum number of Remote I/O Racks + FIM-only Chassis + Remote Mixed
FIM/IO Chassis + Rail Adapters (combined) per C200/CPM.
Maximum number of FF non-redundant Fieldbus Interface Modules (FIMs) per
1,2,3
C200/CPM
Each FIM counts as 2 IO UNITS in the 64 IO/CPM calculations above. See the IO UNIT
Definition Table for details.
Maximum number of FF redundant Fieldbus Interface Modules (FIMs) per
1,2,3
C200/CPM
Each Primary FIM counts as 2 IO UNITS in the 64 IO/CPM calculations above. Each FIM pair
counts as 4 IO Units in the 24 IO Units per downlink CNI calculation. See the IO UNIT
Definition Table for details.
Maximum number of Profibus Modules per C200/CPM
Maximum number of Profibus Modules per downlink CNI
DEVICENET BRIDGE-RELATED:
Maximum number of DNBs (DeviceNet Bridge Modules) per CPM
Maximum number of DNB Modules per downlink CNI
1
Qualified for use with 50 ms CEE and ControlNet or FTE Supervisory Process Control Network. Fieldbus (FIMs) is not supported
on an Experion PKS system that uses Ethernet as the Supervisory Process Control Network .
2
Series D CNI modules are used with the FIM.
3
See EP3-400-200 for more detailed Fieldbus Interface Module specifications.
Experion PKS CEE-based Controller Specifications and Models
IO Device or Module
except where noted elsewhere)
27
December, 2003
Version 1.0
I/O UNITs
1
1
4
1 (for 64 Unit/CPM limit)
1.5 (for 24 Unit/CNI limit)
1
2 (for 64 Unit/CPM limit)
3 (for 24 Unit/CNI limit)
2 (for 64 Unit/CPM limit)
4 (for 24 Unit/CNI limit)
1
1
1 (for 64 Unit/CPM Limit)
1.2 (for 24 Unit/CNI Limit)
2 (for 64 Unit/CPM Limit)
6 (for 24 Unit/CNI Limit)
2 (for 64 Unit/CPM Limit)
2 (for 24 Unit/CNI Limit)
1 (for 24 Unit/CNI Limit)
50 ms CEE
5 ms CEE
4
0
64 I/O Units
12 I/O Units
(Rail I/O not
supported)
24 I/O Units
0 I/O Units
(local I/O)
3
1
2
2
8
0
(local I/O)
21
Not
supported
12
Not
supported
10
2
4 @ 25 ms
Not supported
2 @ 12.5 ms
50 ms CEE
5 ms CEE
32
6
12
Not Supported
1
1