Storage Conditions

The conditions stated below are only valid for modules in their original packed state in
weather protected, non-temperature-controlled storage locations. Normal storage time under
these conditions is 12 months maximum.

Table 24: Storage conditions

Type
Air temperature:
Low
High
Humidity relative:
Low
High
Condens.
Air pressure:
Low
High
Movement of surrounding air
Water: rain, dripping, icing and
frosting
Radiation:
Solar
Heat
Chemically active substances
Mechanically active substances
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
Shocks:
Shock spectrum
Duration
Acceleration
AC75_HD_V00.202
Condition
Unit
-40
°C
+85
10
%
90 at 30°C
90-100 at 30°C
70
kPa
106
1.0
m/s
Not allowed
---
2
1120
W/m
600
Not
recommended
Not
recommended
1.5
mm
2
5
m/s
2-9 9-200
Hz
semi-sinusoidal
1
ms
2
50
m/s
Page 84 of 120
s
Reference
ETS 300 019-2-1: T1.2, IEC 68-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
---
ETS 300 019-2-1: T1.2, IEC 68-2-56 Cb
ETS 300 019-2-1: T1.2, IEC 68-2-30 Db
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
---
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
IEC TR 60271-3-1: 1C1L
IEC TR 60271-3-1: 1S1
IEC TR 60271-3-1: 1M2
IEC 68-2-27 Ea