10-2.External Output - Fujitsu AOU30RLXEH Design & Technical Manual

Wall mounted type for extra cold climate area
Hide thumbs Also See for AOU30RLXEH:
Table of Contents

Advertisement

10-2. External output
Use an external output cable with appropriate external dimension, depending on the number of ca-
bles to be installed.
 Indoor unit
• A twisted pair cable (22AWG) should be used. Maximum length of cable is 82 ft (25 m).
• Output voltage: High DC 12 V ± 2 V, Low 0 V.
• Permissible current: 50 mA
• For details, refer to Chapter 10-3.
 When indicator or other components are connected directly
Example: Function setting 60 is set to "00"
Connected unit
LED
 When connecting with a device equipped with a power supply
Example: Function setting 60 is set to "00"
Connected unit
Connected device
(Operation status)
"Combination of external input and output"
Resistor
Relay
- 27 -
on page 29.
PCB
+
1
Connector
-
(CN3)
2
PCB
+
1
Connector
(CN3)
-
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asu30rle

Table of Contents