3.5 Data transmission modules

On request, the FE260 can be fitted with an integral modem, a connection for a separate modem or an
Ethernet interface in order to read out the data from the connected volume corrector by remote data
transmission. Various modules are possible (refer to sections 3.5.1 et seqq.).
For data transfer via the FE260 the EK260 requires at least the software version 2.02.

3.5.1 Integral standard modem

The standard modem is used for connection to the analogue telephone network (PSTN
2
not ISDN
). With the FE260 with integral standard modem, the connection cable with a TAE subscriber plug
is already mounted on the terminal clamps.
The respective connection cable is passed through the smaller plastic gland at the top centre (→ position "b"
in Fig. 4, page 7).
The connection is made
according to the following
configuration:
1
Public Switched Telephone Network
2
Integrated Services Digital Network
Operating Manual
Wire colour
white
a
RX-
brown
b
RX+
pink
a2
TX-
grey
b2
TX+
FE260
1
subscriber socket,