6. Frame counter monitor

Valid and invalid frame counter can be monitored by the drive monitor function.
Please refer to "Monitoring the operation status" of the drive instruction manual about the
detail.
Press "MODE" key twice.
Item display
---
Parameter setting mode
Direction of rotation
Frame counter
Invalid frame counter
Key
LED
operation
display
---
60.0
"MODE"
auf
"MODE"
fr-f
"UP"
m 50
"UP
n 50
- 21 -
Description
The operation frequency is displayed (Operation at
60Hz). (When standard monitor display selection
f710 is set at 0 [operation frequency])
The first basic parameter "auf" (Wizard function)
is displayed.
The direction of rotation is displayed.
(fr-f: forward run, fr-r: reverse run)
Displays
the
frame
communication through the network.
(example): In the case of 50 counts. In the case of
f711 =72 [a communication option reception
counter] setting.
Displays the invalid frame counter numbers of
communication through the network.
(example): In the case of 50 counts. In the case of
f712 =73 [a Communication option Error counter]
setting)
E6581542①