Mitsubishi Electric MELFA BFP-A8787-F Instruction Manual page 56

Iq platform supporting industrial robot
Table of Contents

Advertisement

5Read Current Line of Robot Program
(3) Completion status
The values below are established as completion status:
Setting
Value
1
Successfully completed
2
Specified data (function number, slot number, program number) out of range
3
Program not selected for the target slot
4
(Reserved)
5
(Reserved)
6
(Reserved)
7
(Reserved)
10
NG because of a factor other than 2 to 7
(4) Data description
[Function No]
Selects the target function.
Function number setting allows you to select a work type (read current line) and specify a program name
(designation of ASCII character).
[Slot number]
Select the target slot. Specify a value (factory default: 8) in the range between 1 and the value of param-
eter TASKMAX.
[Program name]
ASCII characters of the output program name.
• Specifying ASCII character
• Specify ASCII program name in 6 words area (12 characters).
• To specify ASCII characters, specify all 12 characters or string data including terminating code. How-
ever, leading and ending whitespace characters (space) are ignored.
For information about ASCII data, available characters, refer to
[Line No]
The line number of the read line is output.
When a program is selected but program is in abeyance (program is not running), the line number of first
line is output.
5-45 How to Operate Program
Description
Page 37, "(4)
Data description".