    Operating.Instructions................. 5 AC Voltage Measurement ..............5 Auto Power Off ..................5 Flashlight ....................5 Battery.Replacement................... 5 Product.Care....................6 Product.Warranty..................6 Product.Disposal.and.Recycling..............6 Product.Support..................7 Introduction Thank.you.for.purchasing.your.REED.R5100.Non-Contact.AC.Voltage. Detector..Please.read.the.following.instructions.carefully.before.using.your. instrument..By.following.the.steps.outlined.in.this.manual.your.detector. will.provide.years.of.reliable.service. Product Quality This.product.has.been.manufactured.in.an.ISO9001.facility.and.has.been. calibrated.during.the.manufacturing.process.to.meet.stated.product. specifications. 1.800.561.8187 information@itm.com www.
  • Page 3: Safety

    Safety •. Never.attempt.to.repair.or.modify.your.instrument..Dismantling.your. product,.other.than.for.the.purpose.of.replacing.batteries,.may.cause. damage.that.will.not.be.covered.under.the.manufacturer's.warranty.. Servicing.should.only.be.provided.by.an.authorized.service.center. •. Do.not.use.if.the.meter.appears.damaged.or.isn't.operating.properly •. Do.not.apply.more.than.the.specified.voltage •. Use.caution.with.voltage.above.30V.AC •. Before.each.use,.verify.operation.by.testing.a.known.working.circuit. that.is.within.the.rating.of.this.unit •. Do.not.rely.on.this.tester.with.shielded.wire •. Operation.may.be.affected.by.differences.in.socket.design.and.type Features •. Suitable.for.outlets.or.against.insulated.wire •. Built-in.flashlight •. Double.insulated.housing.for.increased.safety •. Audible.(buzzer).and.visual.(LED).indicators.when.voltage.present •. For.use.on.50/60Hz.circuits •. Pocket.clip •. Auto.shut.off •. CE.and.UL.approved •. CAT..III.1000V,.CAT..IV.600V.safety.ratings 1.800.561.8187 information@itm.com www.
  • Page 4: Specifications

    Specifications Voltage.Range:. 50.to.1000V.AC Frequency.Range:. 50.to.60Hz Built-in.Flashlight:. Auto.Power.Off:. Yes.(after.3.minutes) Power.Supply:. 2.x.AAA.batteries Overvoltage.Category:. CAT..III.1000V,.CAT..IV.600V Product.Certifications:. CE,.UL Operating.Temperature:. 32.to.104°F.(0.to.40°C) Operating.Humidity:. 0.to.85% Storage.Temperature:. 14.to.122°F.(-10.to.50°C) Dimensions:. 6.3.x.1.x.1".(159.x.25.x.25mm) Weight:. 1.5oz.(42g) Instrument Description 1.. Probe.Tip 2.. Voltage.Detector.Power.Button 3.. Battery.Compartment 4.. Flashlight.Power.Button 5.. Flashlight 1.800.561.8187 information@itm.com www. .com...
  • Page 5: Operating.instructions

    Operating Instructions Press.the.power.button.to.turn.the.meter.on. The.meter.will.beep.and.the.probe.tip.will.begin.to.flash.indicating.it. has.been.turned.on.and.is.functioning.properly. To.turn.the.meter.off,.press.and.hold.the.power.button.until.you.hear. a.beep.and.the.tip.stops.flashing. AC Voltage Measurement Place.the.probe.tip.near.an.AC.voltage.location. The.tip.will.produce.a.steady.glow.and.a.continuous.beep.indicating. the.presence.of.AC.Voltage. IMPORTANT NOTE:.Receptacles.in.recessed.sockets.or.differences.in. socket.may.result.in.false.readings. Auto Power Off After.3.minutes.of.inactivity.the.meter.will.automatically.shut.off The.meter.will.beep.and.stop.flashing.indicating.it.has.turned.off. Flashlight Press.the.flashlight.button.to.turn.the.flashlight.on.or.off. Battery Replacement When.the.battery.gets.low,.the.meter.will.stop.flashing,.even.when.turned. on..You.will.need.to.replace.the.batteries. Using.a.flathead.screwdriver,.slide.open.the.battery.compartment. and.remove.the.batteries.. Place.new.batteries.in.the.meter,.and.re-secure.the.battery. compartment.cover. 1.800.561.8187 information@itm.com www. .com...
  • Page 6: Product.care

    Product Care To.keep.your.instrument.in.good.working.order.we.recommend.the.following: •. Store.your.product.in.a.clean,.dry.place. •. Change.the.battery.as.needed.. •. If.your.instrument.isn't.being.used.for.a.period.of.one.month.or.longer. please.remove.the.battery. •. Clean.your.product.and.accessories.with.biodegradable.cleaner..Do.not. spray.the.cleaner.directly.on.the.instrument..Use.on.external.parts.only. Product Warranty REED.Instruments.guarantees.this.instrument.to.be.free.of.defects. inmaterial.or.workmanship.for.a.period.of.one.(1).year.from.date.of. shipment..During.the.warranty.period,.REED.Instruments.will.repair.or. replace,.at.no.charge,.products.or.parts.of.a.product.that.proves.to.be. defective.because.of.improper.material.or.workmanship,.under.normal. use.and.maintenance..REED.Instruments.total.liability.is.limited.to.repair. or.replacement.of.the.product..REED.Instruments.shall.not.be.liable.for. damages.to.goods,.property,.or.persons.due.to.improper.use.or.through. attempts.to.utilize.the.instrument.under.conditions.which.exceed.the. designed.capabilities..In.order.to.begin.the.warranty.service.process,. please.contact.us.by.phone.at.1-877-849-2127.or.by.email.at.. info@reedinstruments.com.to.discuss.the.claim.and.determine.the. appropriate.steps.to.process.the.warranty. Product Disposal and Recycling Please.follow.local.laws.and.regulations.when.disposing.or.recycling.your. instrument..Your.product.contains.electronic.components.and.must.be. disposed.of.separately.from.standard.waste.products. 1.800.561.8187 information@itm.com www. .com...
  • Page 7: Product.support

    Please visit www.REEDINSTRUMENTS.com for the most up-to-date manuals, datasheets, product guides and software. Product specifications subject to change without notice. All rights reserved. Any unauthorized copying or reproduction of this manual is strictly prohibited without prior written permission from REED Instruments. 1.800.561.8187 information@itm.com www. .com...