Manufacturer-Specific Objects; 7�1 Object 0X5003, Speed Type - IFM Efector 400 RM7 Series Device Manual

Encoder with canopen interface
Table of Contents

Advertisement

Bit
Supported warnings
3���15
Warnings (object 0x6504/0x6503)
7

Manufacturer-specific objects

7.1
Object 0x5003, speed type
The object 0x5003 sets the update time and resolution (steps / second or rpm)
of the speed information� This object affects the speed object (0x6030) and the
acceleration object (0x6040)�
Speed type
0
1
2
3
The speed object is limited to a signed 16-bit value� In order to avoid data overflow
and optimise the accuracy it is recommended to calculate the optimum setting of
the speed type� Also transfer the scaling to the encoder� The amount of data is
limited and overflow is avoided as the calculation of the speed value is based on
the scaled singleturn value�
If the rotation of the shaft is faster than 1000 rpm and the speed type is 0 (steps/s),
a data overflow occurs� In this case a higher resolution is required, i�e� steps/100
ms�
The accuracy of the speed measurement depends on the selected resolution� The
figures in this table should be considered as reference values�
Speed type
0
1
2
3
The table shows from which shaft speed the accuracy of the measured value
deviates less than 1%� In general, the accuracy improves irrespective of the
selected speed type, the higher the shaft rotation is�
Setting
200 ms update time, steps / s
10 ms update time, steps / 10 ms
100 ms update time, steps / 100 ms
200 ms update time, rpm
Shaft rotation
> 100 rpm
> 1000 rpm
> 1000 rpm
> 100 rpm
CANopen encoder
UK
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efector 400 rn7 series

Table of Contents