3.4.11
GetTagStatus
GetTagStatus(tagID: string)
Parameters
● tagID
Return value(s)
A hash table that contains named values. The parameter names are used as keys.
Exceptions
RfReaderApiException
Note
A valid tag ID must be specified for a tag currently within the field before you can get the
status data, or if no tag ID is specified, the first tag within the field will be read
Returns information about the state of the tag as a list of named values within a hash table.
Currently supported entries are:
TagType
MemorySize
Mobile Reader
Function Manual, 02/2009, J31069-D0198-U001-A1-0076
The ID of a tag whose status is to be read as a plain hexadecimal encoded string (i.e.,
each byte is represented by a two-letter hexadecimal number)
: Hashtable {}
Error while communicating with the reader service. Check the Error
member for more information.
Valid values for the air protocol RF300 are:
RF300
Valid values for the air protocol ISO15693 are:
ISO15693
Returns the size of memory in Byte
For RF300 Tags this is only the size of the FRAM